M. Raatikainen, D. O. Arnar, K. Zeppenfeld, J. L. Merino, F. Levya et al., Statistics on the use of cardiac electronic devices and electrophysiological procedures in the European Society of Cardiology countries: 2014 report from the European Heart Rhythm Association, Europace, vol.17, pp.1-75, 2015.

P. J. Bradshaw, P. Stobie, M. W. Knuiman, T. G. Briffa, and M. Hobbs, Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population, Open Heart, vol.1, p.177, 2014.

, Magnetic resonance imaging (MRI) exams (indicator)

M. Brignole, A. Auricchio, G. Baron-esquivias, and P. Bordachar, ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC), European Heart Rhythm Association (EHRA), vol.15, pp.1070-118, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00879501

J. H. Indik, J. R. Gimbel, H. Abe, R. Alkmim-teixeira, U. Birgersdotter-green et al., HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices, Heart Rhythm, vol.14, pp.97-153, 2017.

Y. Cruypeninck, B. Dubourg, P. Michelin, B. Godin, C. Savoye-collet et al., Pacemakers and MRI: a protocol in line with international guidelines and approved by the SFICV (French Society of Cardiovascular Imaging), Diagn Interv Imaging, vol.98, pp.203-218, 2017.
URL : https://hal.archives-ouvertes.fr/hal-01643979

S. Nazarian, M. R. Reynolds, M. P. Ryan, S. D. Wolff, S. A. Mollenkopf et al., Utilization and likelihood of radiologic diagnostic imaging in patients with implantable cardiac defibrillators, J Magn Reson Imaging, vol.43, pp.115-142, 2016.

P. Korantzopoulos, K. P. Letsas, G. Grekas, and J. A. Goudevenos, Pacemaker dependency after implantation of electrophysiological devices, Europace, vol.11, pp.1151-1156, 2009.

R. Luechinger, F. Duru, M. B. Scheidegger, and P. Boesiger, Candinas R. Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs, Pacing Clin Electrophysiol, vol.24, pp.199-205, 2001.

J. Dacher, Joint Position Paper of the Working Group of Pacing and Electrophysiology of the French Society of Cardiology (SFC) and the Société française d'imagerie cardiaque et, Diagnostic and Interventional Imaging, 2020.

R. Luechinger, F. Duru, V. A. Zeijlemaker, M. B. Scheidegger, P. Boesiger et al., Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields?, Pacing Clin Electrophysiol, vol.25, pp.1419-1442, 2002.

J. V. Higgins, S. H. Sheldon, R. E. Watson, C. Dalzell, N. Acker et al., Power-on resets'' in cardiac implantable electronic devices during magnetic resonance imaging, Heart Rhythm, vol.12, pp.540-544, 2015.

J. R. Gimbel, Unexpected asystole during 3 T magnetic resonance imaging of a pacemaker-dependent patient with a ''modern'' pacemaker, Europace, vol.11, pp.1241-1243, 2009.

S. Maffè, P. Paffoni, A. Perucca, F. Signorotti, P. Dellavesa et al., Pseudo ''end of life'' indication after electromagnetic field exposure: an unusual effect of magnetic resonance imaging on implanted cardioverter defibrillator, Int J Cardiol, vol.156, pp.36-45, 2012.

T. Zaremba, A. R. Jakobsen, A. M. Thøgersen, L. Oddershede, and S. Riahi, The effect of radiotherapy beam energy on modern cardiac devices: an in vitro study, Europace, vol.16, pp.612-618, 2014.

R. Luechinger, V. A. Zeijlemaker, E. M. Pedersen, P. Mortensen, E. Falk et al., In vivo heating of pacemaker leads during magnetic resonance imaging, Eur Heart J, vol.26, pp.376-83, 2005.

L. Horwood, A. Attili, F. Luba, E. Ibrahim, H. Parmar et al., Magnetic resonance imaging in patients with cardiac implanted electronic devices: focus on contraindications to magnetic resonance imaging protocols, Europace, vol.19, pp.812-819, 2017.

J. M. Fontaine, F. B. Mohamed, C. Gottlieb, D. J. Callans, and F. E. Marchlinski, Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging, Pacing Clin Electrophysiol, vol.21, pp.1336-1345, 1998.

B. Nowak, Ist die asynchrone ventrikuläre Schrittmacherstimulation gefährlich?, Dtsch med Wochenschr, vol.130, pp.997-1001, 2005.

W. Irnich, B. Irnich, C. Bartsch, W. A. Stertmann, H. Gufler et al., Do we need pacemakers resistant to magnetic resonance imaging?, Europace, vol.7, pp.353-65, 2005.

S. Nazarian, R. Hansford, A. A. Rahsepar, V. Weltin, D. Mcveigh et al., Safety of magnetic resonance imaging in patients with cardiac devices, N Engl J Med, vol.377, pp.2555-64, 2017.

F. Buendía, Ó. Cano, J. M. Sánchez-gómez, B. Igual, J. Osca et al., Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices, Europace, vol.13, pp.533-541, 2011.

C. P. Naehle, J. Kreuz, K. Strach, J. O. Schwab, S. Pingel et al., Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/defibrillators at 1.5 T, Am Heart J, vol.161, pp.1096-105, 2011.

T. Sasaki, R. Hansford, M. M. Zviman, A. Kolandaivelu, D. A. Bluemke et al., Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators, Circ Cardiovasc Imaging, vol.4, pp.662-70, 2011.

S. Hilbert, C. Jahnke, S. Loebe, S. Oebel, A. Weber et al., Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: a devicedependent imaging strategy for improved image quality, Eur Heart J Cardiovasc Imaging, vol.19, pp.1051-61, 2018.

M. G. Bongiorni, C. Kennergren, C. Butter, J. C. Deharo, A. Kutarski et al., The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) registry of transvenous lead extraction outcomes, Eur Heart J, vol.38, pp.2995-3005, 2017.
URL : https://hal.archives-ouvertes.fr/hal-01760685

H. L. Friedman, N. Acker, C. Dalzell, W. K. Shen, S. J. Asirvatham et al., Magnetic resonance imaging in patients with recently implanted pacemakers, Pacing Clin Electrophysiol, vol.36, pp.1090-1095, 2013.

R. J. Russo, H. S. Costa, P. D. Silva, J. L. Anderson, A. Arshad et al., Assessing the risks associated with MRI in patients with a pacemaker or defibrillator, N Engl J Med, vol.376, pp.755-64, 2017.

K. Awad, J. Griffin, T. C. Crawford, L. Cox, S. Ferrick et al., Clinical safety of the Iforia implantable cardioverterdefibrillator system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions, Heart Rhythm, vol.12, pp.2155-61, 2015.

A. Savouré, A. Mechulan, M. Burban, A. Olivier, and A. Lazarus, The Kora pacemaker is safe and effective for magnetic resonance imaging, Clin Med Insights Cardiol, vol.9, pp.85-90, 2015.

J. Shenthar, G. Milasinovic, A. Fagih, A. Götte, M. Engel et al., MRI scanning in patients with new and existing CapSureFix Novus 5076 pacemaker leads: randomized trial results, Heart Rhythm, vol.12, pp.759-65, 2015.

J. R. Gimbel, D. Bello, M. Schmitt, B. Merkely, J. Schwitter et al., Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla, Heart Rhythm, vol.10, pp.685-91, 2013.

B. L. Wilkoff, D. Bello, M. Taborsky, J. Vymazal, E. Kanal et al., Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment, Heart Rhythm, vol.8, pp.65-73, 2011.

M. R. Gold, T. Sommer, J. Schwitter, A. Fagih, A. Albert et al., Full-body MRI in patients with an implantable cardioverter-defibrillator: primary results of a randomized study, J Am Coll Cardiol, vol.65, pp.2581-2589, 2015.

W. M. Bailey, L. Rosenthal, L. Fananapazir, M. Gleva, A. Mazur et al., Clinical safety of the ProMRI pacemaker system in patients subjected to head and lower lumbar 1.5-T magnetic resonance imaging scanning conditions, Heart Rhythm, vol.12, pp.1183-91, 2015.

W. M. Bailey, A. Mazur, C. Mccotter, P. K. Woodard, L. Rosenthal et al., Clinical safety of the ProMRI pacemaker system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions, Heart Rhythm, vol.13, pp.464-71, 2016.

B. L. Wilkoff, T. Albert, M. Lazebnik, S. Park, J. Edmonson et al., Safe magnetic resonance imaging scanning of patients with cardiac rhythm devices: a role for computer modeling, Heart Rhythm, vol.10, pp.1815-1836, 2013.

T. Sommer, W. Bauer, K. Fischbach, C. Kolb, R. Luechinger et al., MR imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators, Rofo, vol.189, pp.204-221, 2017.

C. P. Naehle, C. Meyer, D. Thomas, S. Remerie, C. Krautmacher et al., Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: pilot prospective study with 51 examinations, Radiology, vol.249, pp.991-1001, 2008.

D. A. Langman, I. B. Goldberg, J. P. Finn, and D. B. Ennis, Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1

M. Tesla, J Magn Reson Imaging, vol.33, pp.426-457, 2011.

K. Strach, C. P. Naehle, A. Mühlsteffen, M. Hinz, A. Bernstein et al., Low-field magnetic resonance imaging: increased safety for pacemaker patients?, Europace, vol.12, pp.952-60, 2010.

E. Kanal, Safety of MR imaging in patients with retained epicardial pacer wires, AJR Am J Roentgenol, vol.170, pp.213-217, 1998.

A. F. Pulver, M. D. Puchalski, D. J. Bradley, L. L. Minich, J. T. Su et al., Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers, Pacing Clin Electrophysiol, vol.32, pp.450-456, 2009.

J. V. Higgins, J. J. Gard, S. H. Sheldon, R. E. Espinosa, C. P. Wood et al., Safety and outcomes of magnetic resonance imaging

J. Dacher, Joint Position Paper of the Working Group of Pacing and Electrophysiology of the French Society of Cardiology (SFC) and the Société française d'imagerie cardiaque et, Diagnostic and Interventional Imaging, 2020.

, ARTICLE IN PRESS +Model DIII-1277; No. of Pages 11

, MRI in patients with cardiac electronic implantable devices: Joint Position Paper of the SFC and SFICV 11 in patients with abandoned pacemaker and defibrillator leads, Pacing Clin Electrophysiol, vol.37, pp.1284-90, 2014.

J. Keller, P. Neu?il, J. Vymazal, M. Janotka, J. Brada et al., Magnetic resonance imaging in patients with a subcutaneous implantable cardioverter-defibrillator, Europace, vol.17, pp.761-767, 2015.

H. Blessberger, D. Kiblboeck, C. Reiter, T. Lambert, J. Kellermair et al., Monocenter Investigation Micra ® MRI study (MIMICRY): feasibility study of the magnetic resonance imaging compatibility of a leadless pacemaker system, Europace, vol.21, pp.137-178, 2019.