Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system - Inserm - Institut national de la santé et de la recherche médicale Accéder directement au contenu
Article Dans Une Revue Journal of Clinical Monitoring and Computing Année : 2017

Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system

Résumé

Non-invasive respiratory variations in arterial pulse pressure using infrared-plethysmography (PPVCNAP) are able to predict fluid responsiveness in mechanically ventilated patients. However, they cannot be continuously monitored. The present study evaluated a new algorithm allowing continuous measurements of PPVCNAP (PPVCNAPauto) (CNSystem, Graz, Austria). Thirty-five patients undergoing vascular surgery were studied after induction of general anaesthesia. Stroke volume was measured using the VigileoTM/FloTracTM. Invasive pulse pressure variations were manually calculated using an arterial line (PPVART) and PPVCNAPauto was continuously displayed. PPVART and PPVCNAPauto were simultaneously recorded before and after volume expansion (500 ml hydroxyethylstarch). Subjects were defined as responders if stroke volume increased by ≥15 %. Twenty-one patients were responders. Before volume expansion, PPVART and PPVCNAPauto exhibited a bias of 0.1 % and limits of agreement from -7.9 % to 7.9 %. After volume expansion, PPVART and PPVCNAPauto exhibited a bias of -0.4 % and limits of agreement from -5.3 % to 4.5 %. A 14 % baseline PPVART threshold discriminated responders with a sensitivity of 86 % (95 % CI 64-97 %) and a specificity of 100 % (95 % CI 77-100 %). Area under the receiver operating characteristic (ROC) curve for PPVART was 0.93 (95 % CI 0.79-0.99). A 15 % baseline PPVCNAPauto threshold discriminated responders with a sensitivity of 76% (95 % CI 53-92 %) and a specificity of 93 % (95 % CI 66-99 %). Area under the ROC curves for PPVCNAPauto was 0.91 (95 % CI 0.76-0.98), which was not different from that for PPVART. When compared with PPVART, PPVCNAPauto performs satisfactorily in assessing fluid responsiveness in hemodynamically stable surgical patients.
Fichier non déposé

Dates et versions

inserm-02469633 , version 1 (06-02-2020)

Identifiants

Citer

Matthieu Biais, Laurent Stecken, Aurélie Martin, Stéphanie Roullet, Alice Quinart, et al.. Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system. Journal of Clinical Monitoring and Computing, 2017, 31 (4), pp.685-692. ⟨10.1007/s10877-016-9899-4⟩. ⟨inserm-02469633⟩

Collections

INSERM CNRS U1034
15 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More