J. H. Boyd, J. Forbes, T. Nakada, K. R. Walley, and J. A. Russell, Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality, Crit Care Med, vol.39, pp.259-65, 2011.

M. Cecconi, C. Hofer, J. Teboul, V. Pettila, E. Wilkman et al., Fluid challenges in intensive care: the FENICE study: a global inception cohort study, Intensive Care Med, vol.41, pp.1529-1566, 2015.
URL : https://hal.archives-ouvertes.fr/hal-01913415

T. Boulain, J. Boisrame-helms, S. Ehrmann, J. Lascarrou, A. Bouglé et al., Volume expansion in the first 4 days of shock: a prospective multicentre study in 19 French intensive care units, Intensive Care Med, vol.41, pp.248-56, 2015.

P. E. Marik, R. Cavallazzi, T. Vasu, and A. Hirani, Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature, Crit Care Med, vol.37, pp.2642-2649, 2009.

Y. Mahjoub, V. Lejeune, L. Muller, S. Perbet, L. Zieleskiewicz et al., Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study, Br J Anaesth, vol.112, pp.681-686, 2014.
URL : https://hal.archives-ouvertes.fr/hal-01954170

M. Biais, S. Ehrmann, A. Mari, B. Conte, Y. Mahjoub et al., Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach, Crit Care Lond Engl, vol.18, p.587, 2014.
URL : https://hal.archives-ouvertes.fr/hal-01945321

S. N. Myatra, N. R. Prabu, J. V. Divatia, X. Monnet, A. P. Kulkarni et al., The changes in pulse pressure variation or stroke volume variation after a "tidal volume challenge" reliably predict fluid responsiveness during low tidal volume ventilation, Crit Care Med, vol.45, pp.415-436, 2017.

X. Monnet, D. Osman, C. Ridel, B. Lamia, C. Richard et al., Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients, Crit Care Med, vol.37, pp.951-957, 2009.

M. Biais, R. Lanchon, M. Sesay, L. Gall, L. Pereira et al., Changes in stroke volume induced by lung recruitment maneuver predict fluid responsiveness in mechanically ventilated patients in the operating room, Anesthesiology, vol.126, pp.260-267, 2017.

A. Vieillard-baron, P. H. Mayo, P. Vignon, B. Cholley, M. Slama et al., Expert Round Table on Echocardiography in ICU. International consensus statement on training standards for advanced critical care echocardiography, Intensive Care Med, vol.40, pp.654-66, 2014.

M. Wetterslev, H. Møller-sørensen, R. R. Johansen, and A. Perner, Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable, Intensive Care Med, vol.42, pp.1223-1256, 2016.

X. Monnet, R. Persichini, M. Ktari, M. Jozwiak, C. Richard et al., Precision of the transpulmonary thermodilution measurements, Crit Care Lond Engl, vol.15, p.204, 2011.

F. Michard, S. Boussat, D. Chemla, N. Anguel, A. Mercat et al., Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure, Am J Respir Crit Care Med, vol.162, pp.134-142, 2000.

E. R. Delong, D. M. Delong, and D. L. Clarke-pearson, Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach, Biometrics, vol.44, pp.837-882, 1988.

P. Ray, L. Manach, Y. Riou, B. Houle, and T. T. , Statistical evaluation of a biomarker, Anesthesiology, vol.112, pp.1023-1063, 2010.

X. Monnet, A. Bleibtreu, A. Ferré, M. Dres, R. Gharbi et al., Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance, Crit Care Med, vol.40, pp.152-159, 2012.

M. Jozwiak, F. Depret, J. Teboul, A. Lai, C. Richard et al., Predicting fluid responsiveness in critically ill patients by using combined end-expiratory and end-inspiratory occlusions with echocardiography, Crit Care Med, vol.45, pp.1131-1139, 2017.

M. Slama, H. Masson, J. Teboul, M. Arnout, D. Susic et al., Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness, Am J Physiol Heart Circ Physiol, vol.283, pp.1729-1762, 2002.

B. Lamia, A. Ochagavia, X. Monnet, D. Chemla, C. Richard et al., Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity, Intensive Care Med, vol.33, pp.1125-1157, 2007.

M. Feissel, F. Michard, I. Mangin, O. Ruyer, J. P. Faller et al., Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock, Chest, vol.119, pp.867-73, 2001.

M. Jozwiak, X. Monnet, R. Cinotti, F. Bontemps, J. Reignier et al., Prospective assessment of a score for assessing basic critical-care transthoracic echocardiography skills in ventilated critically ill patients, Ann Intensive Care, vol.4, p.12, 2014.

M. Biais, V. Cottenceau, L. Stecken, M. Jean, L. Ottolenghi et al., Evaluation of stroke volume variations obtained with the pressure recording analytic method, Crit Care Med, vol.40, pp.1186-91, 2012.

L. Muller, M. Toumi, P. Bousquet, B. Riu-poulenc, G. Louart et al., An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study, Anesthesiology, vol.115, pp.541-548, 2011.

M. Biais, M. Larghi, J. Henriot, H. De-courson, M. Sesay et al., End-expiratory occlusion test predicts fluid responsiveness in patients with protective ventilation in the operating room, Anesth Analg, vol.125, pp.1889-95, 2017.