J. Pan and W. J. Tompkins, A Real-Time QRS Detection Algorithm, IEEE Transactions on Biomedical Engineering, vol.32, issue.3, pp.230-236, 1985.

A. I. Hernández, G. Carrault, F. Mora, L. Thoraval, G. Passariello et al., Multisensor fusion for atrial and ventricular activity detection in coronary care monitoring, IEEE transactions on bio-medical engineering, vol.46, issue.10, pp.1186-1190, 1999.

B. Hansen, Robust Detection of Heart Beats in Multimodal Data: the PhysioNet/ CINC, 2014.

B. Kohler, C. Hennig, and R. Orglmeister, The principles of software QRS detection, IEEE Engineering in Medicine and Biology Magazine, vol.21, issue.1, pp.42-57, 2002.

S. Jain, M. K. Ahirwal, A. Kumar, V. Bajaj, and G. K. Singh, QRS detection using adaptive filters: A comparative study, ISA Transactions, vol.66, pp.362-375, 2017.

S. Osowski and L. Tran, ECG Beat Recognition Using Fuzzy Hybrid Neural Network, vol.48, 2001.

Z. Zidelmal, A. Amirou, D. Ould-abdeslam, A. Moukadem, and A. Dieterlen, QRS detection using S-Transform and Shannon energy, Computer Methods and Programs in Biomedicine, vol.116, issue.1, pp.1-9, 2014.

C. Li, C. Zheng, and C. Tai, Detection of ECG characteristic points using wavelet transform, vol.42, 1995.

D. Benitez, P. A. Gaydecki, A. Zaidi, and A. P. Fitzpatrick, The use of the Hilbert transform in ECG signal analysis, Computers in Biology and Medicine, vol.31, issue.5, pp.9-9, 2001.

Z. Zidelmal, A. Amirou, M. Adnane, and A. Belouchrani, QRS detection based on wavelet coefficients, Computer Methods and Programs in Biomedicine, vol.107, issue.3, pp.490-496, 2012.

G. M. Friesen, T. C. Jannett, M. A. Jadallah, S. L. Yates, S. R. Quint et al., A comparison of the noise sensitivity of nine QRS detection algorithms, IEEE Transactions on Biomedical Engineering, vol.37, issue.1, pp.85-98, 1990.

M. Elgendi, B. Eskofier, S. Dokos, and D. Abbott, Revisiting QRS detection methodologies for portable, wearable, battery-operated, and wireless ECG systems, PloS one, vol.9, issue.1, pp.84018-84018, 2014.

H. Khamis, R. Weiss, Y. Xie, C. W. Chang, N. H. Lovell et al., QRS Detection Algorithm for Telehealth Electrocardiogram Recordings, IEEE Transactions on Biomedical Engineering, vol.63, pp.1377-1388, 2016.

M. Elgendi, M. A. Ward, and R. K. , Efficient ECG Compression and QRS Detection for E-Health Applications. In: Scientific Reports, 2017.

J. Kim and H. Shin, Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex, PloS one, vol.11, 2016.

M. M. Baig, H. Gholamhosseini, and M. J. Connolly, A comprehensive survey of wearable and wireless ECG monitoring systems for older adults, Medical & Biological Engineering & Computing, vol.51, issue.5, pp.485-495, 2013.

C. J. Deepu, X. Xu, X. Zou, L. Yao, and Y. Lian, An ECG-on-Chip for Wearable Cardiac Monitoring Devices, 2010 Fifth IEEE International Symposium on Electronic Design, pp.225-228, 2010.

D. M. Goldenholz, A. Kuhn, A. Austermuehle, M. Bachler, C. C. Mayer et al., Long-term monitoring of cardiorespiratory patterns in drug-resistant epilepsy, Epilepsia, vol.58, pp.77-84, 2017.

F. Portet, A. Hernandez, and G. G. Carrault, Evaluation of real-time QRS detection algorithms in variable contexts, Medical & biological engineering & computing, vol.43, pp.379-85, 2005.
URL : https://hal.archives-ouvertes.fr/inria-00001102

J. Dumont, A. Hernandez, and G. Carrault, Improving ECG Beats Delineation With an Evolutionary Optimization Process, Biomedical Engineering, vol.57, pp.607-615, 2010.
URL : https://hal.archives-ouvertes.fr/inserm-00361377

M. Altuve, G. Carrault, J. Cruz, A. Beuchae, P. Pladys et al., Analysis of the QRS Complex for Apnea-Bradycardia Characterization in Preterm Infants, Conference proceedings: Annual International Conference of the IEEE, pp.946-955, 2009.
URL : https://hal.archives-ouvertes.fr/inserm-00439966

D. Hernando, . Bailó-n-r, R. Almeida, and A. I. Hernández, QRS detection optimization in stress test recordings using evolutionary algorithms. Computing in Cardiology, pp.737-740, 2014.

G. B. Moody, W. K. Muldrow, and R. G. Mark, NOISE STRESS TEST FOR ARRHYTHMIA DETECTORS. Computers in Cardiology, vol.11, pp.381-384, 1984.

P. S. Hamilton and W. J. Tompkins, Quantitative investigation of QRS detection rules using MIT/BIH Arrhythmia database, Biomedical Engineering, vol.33, pp.1157-1165, 1987.

M. Gil, F. Alajaji, and T. Linder, Rényi divergence measures for commonly used univariate continuous distributions, Information Sciences, vol.249, pp.124-131, 2013.

J. R. Mathiassen, A. Skavhaug, and K. Bø, Texture Similarity Measure Using Kullback-Leibler Divergence between Gamma Distributions, pp.133-147, 2002.

M. Elgendi, Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases, PLOS ONE, vol.8, issue.9, pp.1-18, 2013.

J. Kim and H. Shin, Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex, PLOS ONE, vol.11, issue.3, pp.1-13, 2016.

J. P. Martínez, R. Almeida, S. Olmos, A. P. Rocha, and P. Laguna, A Wavelet-Based ECG Delineator: Evaluation on Standard Databases, IEEE transactions on bio-medical engineering, vol.51, pp.570-81, 2004.

M. Llamedo, ecg-kit a Matlab Toolbox for Cardiovascular Signal Processing, Journal of Open Research Software, vol.4, p.8, 2016.

A. Goldberger, L. Amaral, L. Glass, J. Hausdorff, P. Ivanov et al., Components of a New Research Resource for Complex Physiologic Signals, vol.101, pp.215-235, 2000.

F. Liu, C. Liu, L. Zhao, X. Jiang, Z. Zhang et al., Dynamic ECG Signal Quality Evaluation Based on the Generalized bSQI Index, IEEE Access, vol.6, pp.41892-41902, 2018.

B. Hansen, University of Wisconsin. Madison, US. Bandwidth selection for nonparametric distribution estimation, 2004.

M. Do and M. Vetterli, Wavelet-based Texture Retrieval using Generalized Gaussian Density and Kullback-Leibler Distance, IEEE Signal Processing Society, vol.11, pp.146-58, 2002.

, Robust, real-time generic detector based on a multi-feature probabilistic method, PLOS ONE, 201922-10-29.