SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results - Inserm - Institut national de la santé et de la recherche médicale Accéder directement au contenu
Article Dans Une Revue Journal of Neurointerventional Surgery Année : 2019

SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results

Laurent Spelle
Michel Piotin
Charbel Mounayer

Résumé

Flow diversion is an innovative and increasingly used endovascular treatment for intracranial aneurysms. Its initial evaluation with the first devices available showed good efficacy of this treatment with variable safety results. The Flow Direction Endoluminal Device (FRED) has a specific design and was evaluated in a single-arm, multicenter, prospective, Good Clinical Practice study: SAFE (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment). This analysis reports clinical results at 1 year and anatomical results at 6 months and 1 year. METHODS: Patients with unruptured and recanalized aneurysms located in the anterior circulation treated with FRED and FRED Jr were prospectively included. A Clinical Event Committee and a Core Laboratory independently evaluated clinical outcome and anatomical results. RESULTS: Thirteen interventional neuroradiology centers included 103 patients/aneurysms. Aneurysm locations were supraclinoid internal carotid artery (ICA) in 71 (68.9%), cavernous ICA in 15 (14.6%), anterior cerebral or anterior communicating artery in 9 (8.7%), and middle cerebral artery in 8 (7.8%). Most aneurysms were small (<10 mm) in 71 patients (68.9%). Cumulative 1-year mortality and morbidity rates were 2/103 (1.9%) and 3/103 (2.9%), respectively, one death being related to cancer. At 1 year, anatomical results were: complete occlusion in 66/90 patients (73.3%), neck remnant in 7/90 patients (7.8%), and aneurysm remnant in 17/90 patients (18.9%). CONCLUSIONS: SAFE study analysis at 1 year confirms the excellent safety profile of the FRED device for aneurysm treatment, with low morbidity and mortality rates (2.9% and 1.9%, respectively) and demonstrates its efficacy (adequate occlusion in 73/90 (81.1%)). CLINICAL TRIAL REGISTRATION: Unique identifier: NCT02921698; Results.

Mots clés

Fichier principal
Vignette du fichier
184.full.pdf (989.29 Ko) Télécharger le fichier
Origine : Publication financée par une institution
Loading...

Dates et versions

inserm-02444419 , version 1 (17-01-2020)

Identifiants

Citer

Laurent Pierot, Laurent Spelle, Jérôme Berge, Anne-Christine Januel, Denis Herbreteau, et al.. SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical results. Journal of Neurointerventional Surgery, 2019, 11 (2), pp.184-189. ⟨10.1136/neurintsurg-2018-014261⟩. ⟨inserm-02444419⟩
49 Consultations
121 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More