O. Adunka and J. Kiefer, Impact of electrode insertion depth on intracochlear trauma, Otolaryngology-Head and Neck Surgery, vol.102, issue.3, pp.374-382, 2006.
DOI : 10.1121/1.420354

A. Aschendorff, J. Kromeier, T. Klenzner, and R. Laszig, Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults, Ear and Hearing, vol.28, issue.Supplement, pp.75-79, 2007.
DOI : 10.1097/AUD.0b013e318031542e

F. Atturo, M. Barbara, and H. Rask-andersen, On the Anatomy of the ‘Hook' Region of the Human Cochlea and How It Relates to Cochlear Implantation, Audiology and Neurotology, vol.19, issue.6, pp.378-385, 2014.
DOI : 10.1159/000365585

S. Biedron, A. Prescher, J. Ilgner, and M. Westhofen, The Internal Dimensions of the Cochlear Scalae With Special Reference to Cochlear Electrode Insertion Trauma, Otology & Neurotology, vol.31, issue.5, pp.31-731, 2010.
DOI : 10.1097/MAO.0b013e3181d27b5e

E. Boyer, A. Karkas, A. Attye, V. Lefournier, B. Escude et al., Scalar Localization by Cone-Beam Computed Tomography of Cochlear Implant Carriers, Otology & Neurotology, vol.36, issue.3, pp.422-429, 2015.
DOI : 10.1097/MAO.0000000000000705

URL : https://hal.archives-ouvertes.fr/dumas-01122663

R. J. Briggs, M. Tykocinski, R. Lazsig, A. Aschendorff, T. Lenarz et al., Development and evaluation of the modiolar research array ??? multi-centre collaborative study in human temporal bones, Cochlear Implants International, vol.12, issue.3, pp.129-139, 2011.
DOI : 10.1179/cim.2009.10.Supplement-1.115

M. L. Carlson, C. L. Driscoll, R. H. Gifford, G. J. Service, N. M. Tombers et al., Implications of Minimizing Trauma During Conventional Cochlear Implantation, Otology & Neurotology, vol.32, issue.6, pp.962-968, 2011.
DOI : 10.1097/MAO.0b013e3182204526

URL : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4127076/pdf

J. Doshi, P. Johnson, D. Mawman, K. Green, I. A. Bruce et al., Straight Versus Modiolar Hugging Electrodes, Otology & Neurotology, vol.36, issue.2, pp.223-227, 2015.
DOI : 10.1097/MAO.0000000000000603

D. Seta, D. Nguyen, Y. Bonnard, D. Ferrary, E. Godey et al., The Role of Electrode Placement in Bilateral Simultaneously Cochlear-Implanted Adult Patients, Otolaryngology-Head and Neck Surgery, vol.34, issue.3, pp.485-493, 2016.
DOI : 10.1097/MAO.0000000000000955

URL : https://hal.archives-ouvertes.fr/hal-01323528

B. Escud-e, C. James, O. Deguine, N. Cochard, E. Eter et al., The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes, Audiology and Neurotology, vol.47, issue.1, pp.11-27, 2006.
DOI : 10.1121/1.399052

A. A. Eshraghi, D. M. Lang, J. Roell, T. R. Van-de-water, C. Garnham et al., Mechanisms of programmed cell death signaling in hair cells and support cells post-electrode insertion trauma, Acta Oto-Laryngologica, vol.28, issue.4, pp.328-334, 2015.
DOI : 10.1523/JNEUROSCI.4914-07.2008

L. K. Holden, C. C. Finley, J. B. Firszt, T. A. Holden, C. Brenner et al., Factors affecting open-set word recognition in adults with cochlear implants Ear Hear, pp.342-360, 2013.

T. Ishii, M. Takayama, and Y. Takahashi, Mechanical Properties of Human Round Window, Basilar and Reissner's Membranes, Acta Oto-Laryngologica, vol.47, issue.sup519, pp.78-82, 1995.
DOI : 10.1177/000348943804700102

A. Jeyakumar, S. F. Pe~-na, and T. M. Brickman, Round Window Insertion of Precurved Electrodes Is Traumatic, Otology & Neurotology, vol.35, issue.1, pp.52-57, 2014.
DOI : 10.1097/MAO.0000000000000194

T. Kamakura, N. Jr, and J. B. , Correlation between word recognition score and intracochlear new bone and fibrous tissue after cochlear implantation in the human, Hearing Research, vol.339, issue.16, pp.378-595530135, 2016.
DOI : 10.1016/j.heares.2016.06.015

D. W. Kennedy, MULTICHANNEL INTRACOCHLEAR ELECTRODES, The Laryngoscope, vol.97, issue.1, pp.42-49, 1987.
DOI : 10.1288/00005537-198701000-00011

G. Kontorinis, T. Lenarz, T. St?-over, and G. Paasche, Impact of the Insertion Speed of Cochlear Implant Electrodes on the Insertion Forces, Otology & Neurotology, vol.32, issue.4, pp.565-570, 2011.
DOI : 10.1097/MAO.0b013e318219f6ac

G. Kontorinis, G. Paasche, T. Lenarz, and T. St?-over, The Effect of Different Lubricants on Cochlear Implant Electrode Insertion Forces, Otology & Neurotology, vol.32, issue.7, 2011.
DOI : 10.1097/MAO.0b013e31821b3c88

E. Lehnhardt, Intracochlear placement of cochlear implant electrodes in soft surgery technique, Dtsch. Ges. Hals Nasen Ohren? arzte Zeitschaft Nasen Ohrenheilkd. 41, pp.356-359, 1993.

T. Lenarz, T. Stover, A. Buechner, G. Paasche, R. Briggs et al., Temporal Bone Results and Hearing Preservation with a New Straight Electrode, Audiology and Neurotology, vol.61, issue.1, pp.11-34, 2006.
DOI : 10.1044/1059-0889(1999/002)

O. Majdani, D. Schurzig, A. Hussong, T. Rau, J. Wittkopf et al., Force measurement of insertion of cochlear implant electrode arrays in vitro: comparison of surgeon to automated insertion tool, Acta Oto-Laryngologica, vol.519, issue.1, pp.31-36, 2010.
DOI : 10.3109/00016489509121875

R. Martinez-monedero, J. K. Niparko, and N. Aygun, Cochlear Coiling Pattern and Orientation Differences in Cochlear Implant Candidates, Otology & Neurotology, vol.32, issue.7, 2011.
DOI : 10.1097/MAO.0b013e31822a1ee2

G. Martins, S. De, R. V. Brito-neto, R. K. Tsuji, E. M. Gebrim et al., Evaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window, BioMed Research International, vol.89, issue.1, p.236364, 2015.
DOI : 10.1007/bf00453760

X. Meshik, T. A. Holden, R. A. Chole, and T. E. Hullar, Optimal Cochlear Implant Insertion Vectors, Otology & Neurotology, vol.31, issue.1, pp.31-58, 2010.
DOI : 10.1097/MAO.0b013e3181b76bb8

URL : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2818088/pdf

M. Miroir, Y. Nguyen, G. Kazmitcheff, E. Ferrary, O. Sterkers et al., Friction Force Measurement During Cochlear Implant Insertion, Otology & Neurotology, vol.33, 2012.
DOI : 10.1097/MAO.0b013e31825f24de

URL : https://hal.archives-ouvertes.fr/hal-01148661

P. Mukherjee, H. Uzun-coruhlu, C. C. Wong, I. S. Curthoys, A. S. Jones et al., Assessment of intracochlear trauma caused by the insertion of a new straight research array, Cochlear Implants International, vol.9, issue.3, pp.156-162, 2012.
DOI : 10.1179/cim.2005.6.4.159

N. Jr, J. B. Shiao, J. Y. Burgess, B. J. Ketten, D. R. Eddington et al., Histopathology of cochlear implants in humans, Ann. Otol. Rhinol. Laryngol, vol.110, issue.9, pp.883-891, 2001.

K. F. Nordfalk, K. Rasmussen, E. Hopp, M. Bunne, J. T. Silvola et al., Insertion Depth in Cochlear Implantation and Outcome in Residual Hearing and Vestibular Function, Ear and Hearing, vol.37, issue.2, pp.129-137, 2016.
DOI : 10.1097/AUD.0000000000000241

Y. Nguyen, M. Miroir, G. Kazmitcheff, J. Sutter, M. Bensidhoum et al., Cochlear Implant Insertion Forces in Microdissected Human Cochlea to Evaluate a Prototype Array, Audiology and Neurotology, vol.17, issue.5, pp.290-298, 2012.
DOI : 10.1159/000338406

URL : https://hal.archives-ouvertes.fr/hal-01148662

Y. Nguyen, G. Kazmitcheff, D. De-seta, M. Miroir, E. Ferrary et al., Definition of Metrics to Evaluate Cochlear Array Insertion Forces Performed with Forceps, Insertion Tool, or Motorized Tool in Temporal Bone Specimens, BioMed Research International, vol.32, issue.6, pp.532-570, 2014.
DOI : 10.1097/MAO.0b013e31825f24de

URL : https://hal.archives-ouvertes.fr/hal-01148679

Y. Nguyen, D. Bernardeschi, G. Kazmitcheff, M. Miroir, T. Vauchel et al., Effect of Embedded Dexamethasone in Cochlear Implant Array on Insertion Forces in an Artificial Model of Scala Tympani, Otology & Neurotology, vol.36, issue.2, pp.354-358, 2015.
DOI : 10.1097/MAO.0000000000000521

URL : https://hal.archives-ouvertes.fr/hal-01148680

G. P. Rajan, G. Kontorinis, and J. Kuthubutheen, The Effects of Insertion Speed on Inner Ear Function during Cochlear Implantation: A Comparison Study, Audiology and Neurotology, vol.31, issue.1, pp.17-22, 2013.
DOI : 10.1097/AUD.0b013e3181b7190c

P. Rohani, J. Pile, L. A. Kahrs, R. Balachandran, G. S. Blachon et al., Forces and Trauma Associated with Minimally Invasive Image-Guided Cochlear Implantation, Otolaryngology-Head and Neck Surgery, vol.33, issue.4, pp.638-645, 2014.
DOI : 10.3109/00016480902998281

URL : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4465091/pdf

R. Jr and J. T. , A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique, Laryngoscope, vol.115, 2005.

D. Schurzig, R. J. Webster-3rd, M. S. Dietrich, and R. F. Labadie, Force of Cochlear Implant Electrode Insertion Performed by a Robotic Insertion Tool, Otology & Neurotology, vol.31, issue.8, p.31, 2010.
DOI : 10.1097/MAO.0b013e3181f2ebc3

D. Schuster, L. B. Kratchman, and R. F. Labadie, Characterization of Intracochlear Rupture Forces in Fresh Human Cadaveric Cochleae, Otology & Neurotology, vol.36, issue.4, pp.657-661, 2015.
DOI : 10.1097/MAO.0000000000000573

H. Skarzynski, A. Lorens, M. Matusiak, M. Porowski, P. H. Skarzynski et al., Partial Deafness Treatment with the Nucleus Straight Research Array Cochlear Implant, Audiology and Neurotology, vol.21, issue.2, pp.82-91, 2012.
DOI : 10.1159/000077267

M. W. Skinner, T. A. Holden, B. R. Whiting, A. H. Voie, B. Brunsden et al., In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea, Ann. Otol., Rhinol. Laryngol, vol.197, pp.2-24, 2007.

R. Torres, G. Kazmitcheff, D. Bernardeschi, D. De-seta, J. L. Bensimon et al., Variability of the mental representation of the cochlear anatomy during cochlear implantation, European Archives of Oto-Rhino-Laryngology, vol.17, issue.8, 2016.
DOI : 10.1159/000338406

R. Torres, G. Kazmitcheff, D. De-seta, E. Ferrary, O. Sterkers et al., Improvement of the insertion axis for cochlear implantation with a robot-based system, European Archives of Oto-Rhino-Laryngology, vol.36, issue.Suppl 1, pp.405-421, 2016.
DOI : 10.1007/s00405-016-4063-9

C. Tsai and C. Tseng, The effect of friction reduction in the presence of in-plane vibrations, Archive of Applied Mechanics, vol.75, issue.2-3, pp.164-176, 2006.
DOI : 10.1007/s00419-005-0427-0

G. B. Wanna, J. H. Noble, T. R. Mcrackan, B. M. Dawant, M. S. Dietrich et al., Assessment of Electrode Placement and Audiological Outcomes in Bilateral Cochlear Implantation, Otology & Neurotology, vol.32, issue.3, pp.428-432, 2011.
DOI : 10.1097/MAO.0b013e3182096dc2

G. B. Wanna, J. H. Noble, R. H. Gifford, M. S. Dietrich, A. D. Sweeney et al., Impact of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual Hearing in Cochlear Implant Patients, Otology & Neurotology, vol.36, issue.8, 2015.
DOI : 10.1097/MAO.0000000000000829

D. B. Welling, R. Hinojosa, B. J. Gantz, and J. T. Lee, Insertional Trauma of Multichannel Cochlear Implants, The Laryngoscope, vol.103, issue.9, 1993.
DOI : 10.1288/00005537-199309000-00010

J. Wu, L. Yan, H. Xu, W. C. Tang, and F. G. Zeng, A curvature-controlled 3D microelectrode array for cochlear implants, Proceedings of 13th International Conference Solid-state Sensors, Actuators and Microsystems, pp.1636-1639, 2005.

J. Xu, S. A. Xu, L. T. Cohen, and G. M. Clark, Cochlear view: Postoperative radiography for cochlear implantation, American Journal of Otolaryngology, vol.21, issue.1, pp.49-56, 2000.
DOI : 10.1016/S0196-0709(00)80112-X

J. Zhang, S. Bhattacharyya, and N. Simaan, Model and parameter identification of friction during robotic insertion of cochlear-implant electrode arrays, 2009 IEEE International Conference on Robotics and Automation, pp.3859-3864, 2009.
DOI : 10.1109/ROBOT.2009.5152738

J. Zhang, W. Wei, J. Ding, R. Jr, J. T. Manolidis et al., Inroads Toward Robot-Assisted Cochlear Implant Surgery Using Steerable Electrode Arrays, Otology & Neurotology, vol.31, issue.8, p.31, 2010.
DOI : 10.1097/MAO.0b013e3181e7117e

L. Zhou, D. R. Friedmann, C. Treaba, R. Peng, R. Jr et al., Does cochleostomy location influence electrode trajectory and intracochlear trauma?, The Laryngoscope, vol.117, issue.11 Suppl 1, pp.966-971, 2015.
DOI : 10.1097/MLG.0b013e3181453a6c