On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies, Magnetic Resonance Imaging, vol.24, issue.6, pp.801-812, 2006. ,
DOI : 10.1016/j.mri.2006.01.006
Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating, Journal of Magnetic Resonance Imaging, vol.16, issue.2, pp.315-320, 2004. ,
DOI : 10.1002/jmri.20103
Variability in RF-induced heating of a deep brain stimulation implant across MR systems, Journal of Magnetic Resonance Imaging, vol.57, issue.6, pp.1236-1242, 2006. ,
DOI : 10.1002/jmri.20769
La stereoelectroencephalographie dans l'epilepsie: informations neurophysiopathologiques apportees par l'investigation fonctionelle stereotaxique, 1965. ,
Feasibility of an intracranial EEG???fMRI protocol at 3T: Risk assessment and image quality, NeuroImage, vol.63, issue.3, pp.1237-1248, 2012. ,
DOI : 10.1016/j.neuroimage.2012.08.008
Local generation of fast ripples in epileptic brain, J. Neurosci, vol.22, issue.5, pp.2012-2021, 2002. ,
Functional MRI with active, fully implanted, deep brain stimulation systems: Safety and experimental confounds, NeuroImage, vol.37, issue.2, pp.508-517, 2007. ,
DOI : 10.1016/j.neuroimage.2007.04.058
Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: Radiofrequency-induced heating, Journal of Magnetic Resonance Imaging, vol.52, issue.5, pp.1233-1244, 2008. ,
DOI : 10.1002/jmri.21583
Feasibility of simultaneous intracranial EEG-fMRI in humans: A safety study, NeuroImage, vol.49, issue.1, pp.379-390, 2010. ,
DOI : 10.1016/j.neuroimage.2009.07.062
Simultaneous intracranial EEGfMRI in humans: data quality, Neuroimage, 2012. ,
Intracranial EEG study of seizure-associated nose wiping, Neurology, vol.63, issue.6, pp.1127-1129, 2004. ,
DOI : 10.1212/01.WNL.0000138573.62251.59
Intracranial EEG-fMRI analysis of focal epileptiform discharges in humans, Epilepsia, vol.21, issue.Suppl. 3, pp.1-13, 2012. ,
DOI : 10.1111/j.1528-1167.2012.03601.x
Active deep brain stimulation during MRI: A feasibility study, Magnetic Resonance in Medicine, vol.12, issue.2, pp.380-388, 2004. ,
DOI : 10.1002/mrm.10699
Neurophysiological monitoring for epilepsy surgery: the Talairach SEEG method. StereoElectroEncephaloGraphy. Indications, results, complications and therapeutic applications in a series of 100 consecutive cases, Stereotact. Funct. Neurosurg, vol.77, pp.1-4, 2001. ,
MRI Assessment of the Anatomy of Optic Radiations after Temporal Lobe Epilepsy Surgery, Stereotactic and Functional Neurosurgery, vol.73, issue.1-4, pp.73-84, 1999. ,
DOI : 10.1159/000029760
A Stereoelectroencephalographic (SEEG) Study of Light-Induced Mesiotemporal Epileptic Seizures, 1098?1103, 1998. ,
DOI : 10.1002/ana.410110419
Evidence of peripheral auditory activity modulation by the auditory cortex in humans, Neuroscience, vol.104, issue.2, pp.347-358, 2001. ,
DOI : 10.1016/S0306-4522(01)00072-0
Intracranial EEG and human brain mapping, Journal of Physiology-Paris, vol.97, issue.4-6, pp.613-628, 2003. ,
DOI : 10.1016/j.jphysparis.2004.01.018
Recording of EEG during fMRI experiments: Patient safety, Magnetic Resonance in Medicine, vol.1, issue.6, pp.943-952, 1997. ,
DOI : 10.1002/mrm.1910380614
Independent component analysis reveals dynamic ictal BOLD responses in EEG-fMRI data from focal epilepsy patients, NeuroImage, vol.49, issue.1, pp.366-378, 2010. ,
DOI : 10.1016/j.neuroimage.2009.07.064
URL : https://hal.archives-ouvertes.fr/hal-01246778
Functional Mapping of the Insular Cortex: Clinical Implication in Temporal Lobe Epilepsy, Epilepsia, vol.43, issue.6, pp.681-686, 2000. ,
DOI : 10.1016/S0168-5597(98)00054-9
Radiofrequency heating effects around resonant lengths of wire in MRI, Physics in Medicine and Biology, vol.47, issue.16, pp.47-2973, 2002. ,
DOI : 10.1088/0031-9155/47/16/312
Subthalamic Nucleus Deep Brain Stimulation for Parkinson???s Disease: Magnetic Resonance Imaging Targeting Using Visible Anatomical Landmarks, Stereotactic and Functional Neurosurgery, vol.80, issue.1-4, pp.1-4, 2003. ,
DOI : 10.1159/000075163
Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla, Journal of Magnetic Resonance Imaging, vol.41, issue.3, pp.241-250, 2002. ,
DOI : 10.1002/jmri.10069
Nocturnal Hypermotor Seizures, Suggesting Frontal Lobe Epilepsy, Can Originate in the Insula, Epilepsia, vol.5, issue.4, pp.755-765, 2006. ,
DOI : 10.1016/j.neuroimage.2005.05.028
URL : https://hal.archives-ouvertes.fr/inserm-00388334
Testing MR Safety and Compatibility, IEEE Engineering in Medicine and Biology Magazine, vol.27, issue.3, pp.23-27, 2008. ,
DOI : 10.1109/EMB.2007.910267
Testing methods for MR safety and compatibility of medical devices, Minimally Invasive Therapy & Allied Technologies, vol.47, issue.2, pp.71-75, 2006. ,
DOI : 10.1002/mrm.10004
Radiofrequency heating at 9.4T: In vivo temperature measurement results in swine, Magnetic Resonance in Medicine, vol.9, issue.1, pp.73-78, 2008. ,
DOI : 10.1002/mrm.21425
Imaging haemodynamic changes related to seizures: Comparison of EEG-based general linear model, independent component analysis of fMRI and intracranial EEG, NeuroImage, vol.53, issue.1, pp.196-205, 2010. ,
DOI : 10.1016/j.neuroimage.2010.05.064
URL : https://hal.archives-ouvertes.fr/hal-00617793
Magnetic Resonance Imaging and Deep Brain Stimulation, Neurosurgery, vol.51, issue.6, pp.1423-1428, 2002. ,
DOI : 10.1227/01.NEU.0000309118.55205.E6
Magnetic resonance imaging stereotactic target localization for deep brain stimulation in dystonic children, Journal of Neurosurgery, vol.93, issue.5, pp.784-790, 2000. ,
DOI : 10.3171/jns.2000.93.5.0784
Simultaneous intracranial EEG and fMRI of interictal epileptic discharges in humans, NeuroImage, vol.54, issue.1, pp.182-190, 2010. ,
DOI : 10.1016/j.neuroimage.2010.08.004
Polarization of the RF field in a human head at high field: A study with a quadrature surface coil at 7.0 T, Magnetic Resonance in Medicine, vol.22, issue.2, pp.362-369, 2002. ,
DOI : 10.1002/mrm.10197
Intracranial electrode visualization in invasive pre-surgical evaluation for epilepsy, Conf Proc IEEE Eng Med Biol Soc, vol.1, pp.952-955, 2005. ,
Postoperative MRI examinations in patients treated by deep brain stimulation using a non-standard protocol, Acta Neurochirurgica, vol.74, issue.12, p.152, 2010. ,
DOI : 10.1007/s00701-010-0738-y