F. Morschhauser, F. Kraeber-bodéré, W. Wegener, J. Harousseau, M. Petillon et al., High Rates of Durable Responses With Anti-CD22 Fractionated Radioimmunotherapy: Results of a Multicenter, Phase I/II Study in Non-Hodgkin's Lymphoma, Journal of Clinical Oncology, vol.28, issue.23, pp.3709-3716, 2010.
DOI : 10.1200/JCO.2009.27.7863

T. Illidge, Radioimmunotherapy of Lymphoma: A Treatment Approach Ahead of Its Time or Past Its Sell-By Date?, Journal of Clinical Oncology, vol.28, issue.18, pp.2944-2946, 2010.
DOI : 10.1200/JCO.2009.26.8748

L. Bodei, M. Cremonesi, C. Grana, P. Rocca, M. Bartolomei et al., Receptor radionuclide therapy with 90Y-[DOTA]0-Tyr3-octreotide (90Y-DOTATOC) in neuroendocrine tumours, European Journal of Nuclear Medicine and Molecular Imaging, vol.31, issue.7, pp.1038-1046, 2004.
DOI : 10.1007/s00259-004-1571-4

C. Ansquer, F. Kraeber-bodéré, and J. Chatal, Current Status and Perspectives in Peptide Receptor Radiation Therapy, Current Pharmaceutical Design, vol.15, issue.21, pp.2453-2462, 2009.
DOI : 10.2174/138161209788682262

R. Salem and K. Thurston, Radioembolization with 90Yttrium Microspheres: A State-of-the-Art Brachytherapy Treatment for Primary and Secondary Liver Malignancies, Journal of Vascular and Interventional Radiology, vol.17, issue.8, pp.1251-1278, 2006.
DOI : 10.1097/01.RVI.0000233785.75257.9A

W. Bult, M. Vente, B. Zonnenberg, V. H. Schip, A. Nijsen et al., Microsphere radioembolization of liver malignancies: current developments, Q J Nucl Med Mol Imaging, vol.53, pp.325-335, 2009.

G. Ettorre, R. Santoro, C. Puoti, R. Sciuto, L. Carpanese et al., Short-Term Follow-Up of Radioembolization With Yttrium-90 Microspheres Before Liver Transplantation: New Perspectives in Advanced Hepatocellular Carcinoma, Transplantation, vol.90, issue.8, pp.930-931, 2010.
DOI : 10.1097/TP.0b013e3181f10f04

J. Carrasquillo, J. White, C. Paik, A. Raubitschek, N. Le et al., Similarities and differences in 111In-and 90Y-labeled 1B4M-DTPA antiTac monoclonal antibody distribution, J Nucl Med, vol.40, pp.268-276, 1999.

D. Minarik, G. Sjogreen, and M. Ljungberg, Y SPECT based on experimental phantom studies, Physics in Medicine and Biology, vol.53, issue.20, pp.5689-5703, 2008.
DOI : 10.1088/0031-9155/53/20/008

E. Rault, S. Vandenberghe, S. Staelens, R. Van-holen, and I. Lemahieu, Optimization of 90Y bremsstrahlung image reconstruction using multiple energy window subsets [abstract], J Nucl Med, vol.49, p.399, 2008.

S. Walrand, M. Hesse, G. Demonceau, S. Pauwels, and J. F. , Yttrium-90-labeled microsphere tracking during liver selective internal radiotherapy by bremsstrahlung pinhole SPECT: feasibility study and evaluation in an abdominal phantom, EJNMMI Research, vol.1, issue.1, pp.32-46, 2011.
DOI : 10.1007/s002590050188

R. Selwyn, R. Nickles, B. Thomadsen, L. Dewerd, and J. Micka, A new internal pair production branching ratio of 90Y: The development of a non-destructive assay for 90Y and 90Sr, Applied Radiation and Isotopes, vol.65, issue.3, pp.318-327, 2007.
DOI : 10.1016/j.apradiso.2006.08.009

R. Nickles, A. Roberts, J. Nye, A. Converse, T. Barnhart et al., Assaying and PET imaging of yttrium-90: 1> > 34 ppm > 0.I nIEEE Nuclear Science Symposium Conference Record, pp.3412-3414, 2004.

R. Lhommel, L. Van-elmbt, P. Goffette, M. Van-den-eynde, J. F. Pauwels et al., Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres, European Journal of Nuclear Medicine and Molecular Imaging, vol.51, issue.3, pp.1654-1662, 2010.
DOI : 10.1007/s00259-010-1470-9

V. Gates, A. Esmail, K. Marshall, S. Spies, and R. Salem, Internal Pair Production of 90Y Permits Hepatic Localization of Microspheres Using Routine PET: Proof of Concept, Journal of Nuclear Medicine, vol.52, issue.1, pp.72-76, 2011.
DOI : 10.2967/jnumed.110.080986

S. Walrand, J. F. Van-elmbt, L. Lhommel, R. Bekonde, and E. , 4-Step Renal Dosimetry Dependent on Cortex Geometry Applied to 90Y Peptide Receptor Radiotherapy: Evaluation Using a Fillable Kidney Phantom Imaged by 90Y PET, Journal of Nuclear Medicine, vol.51, issue.12, pp.1969-1973, 2010.
DOI : 10.2967/jnumed.110.080093

S. Baba, K. Abe, H. Sawamoto, Y. Tanabe, Y. Maruoka et al., Visualization and dose estimation of 90Y-ibritumomab-tiukisetan accumulation in lymphoma patients using TOF PET/CT [abstract], J Nucl Med, p.52, 1987.

L. Van-elmbt, S. Vandenberghe, S. Walrand, S. Pauwels, and J. F. , Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy, Physics in Medicine and Biology, vol.56, issue.21, pp.6759-6777, 2011.
DOI : 10.1088/0031-9155/56/21/001

J. Chatal, J. Saccavini, J. Gestin, P. Thédrez, C. Curtet et al., Biodistribution of indium-111-labeled OC 125 monoclonal antibody intraperitoneally injected into patients operated on for ovarian carcinomas, Cancer Res, vol.49, pp.3087-3094, 1989.

B. Jakoby, Y. Bercier, M. Conti, M. Casey, B. Bendriem et al., Physical and clinical performance of the mCT time-of-flight PET/CT scanner, Physics in Medicine and Biology, vol.56, issue.8, pp.2375-2389, 2011.
DOI : 10.1088/0031-9155/56/8/004

R. Lhommel, P. Goffette, M. Van-den-eynde, J. F. Pauwels, S. Bilbao et al., Yttrium-90 TOF PET scan demonstrates high-resolution biodistribution after liver SIRT, European Journal of Nuclear Medicine and Molecular Imaging, vol.6, issue.10, p.1696, 2009.
DOI : 10.1007/s00259-009-1210-1

V. Panin, F. Kehren, C. Michel, and M. Casey, Fully 3-D PET reconstruction with system matrix derived from point source measurements, IEEE Transactions on Medical Imaging, vol.25, issue.7, pp.907-921, 2006.
DOI : 10.1109/TMI.2006.876171

Q. Bao and A. Chatziioannou, Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method, Medical Physics, vol.16, issue.11, pp.6070-6083, 2010.
DOI : 10.1118/1.3495817

A. Goertzen, J. Suk, and C. Thompson, Imaging of Weak-Source Distributions in LSO-Based Small-Animal PET Scanners, Journal of Nuclear Medicine, vol.48, issue.10, pp.1692-1698, 2007.
DOI : 10.2967/jnumed.107.040584

S. Cherry, J. Sorenson, and M. Phelps, Physics in Nuclear Medicine, Medical Physics, vol.31, issue.8, 2003.
DOI : 10.1118/1.1776595

S. Stute, T. Carlier, C. K. Noblet, C. Martineau, A. Hutton et al., Monte Carlo simulations of clinical PET and SPECT scans: impact of the input data on the simulated images, Physics in Medicine and Biology, vol.56, issue.19, pp.6441-6457, 2011.
DOI : 10.1088/0031-9155/56/19/017

D. Bright, D. Newbury, and E. Steel, Visibility of objects in computer simulations of noisy micrographs, Journal of Microscopy, vol.189, issue.1, pp.25-42, 1997.
DOI : 10.1046/j.1365-2818.1998.00249.x

C. Watson, M. Casey, L. Eriksson, T. Mulnix, D. Adams et al., NEMA NU 2 performance tests for scanners with intrinsic radioactivity, J Nucl Med, vol.45, pp.822-826, 2004.

R. Selwyn, J. Micka, L. Dewerd, R. Nickles, and B. Thomadsen, using a nondestructive spectroscopic assay, Medical Physics, vol.65, issue.4, pp.1278-1279, 2008.
DOI : 10.1016/j.apradiso.2003.11.068

G. Shakirin, H. Braess, F. Fielder, D. Kunath, K. Laube et al., Implementation and workflow for PET monitoring of therapeutic ion irradiation: a comparison of in-beam, in-room, and off-line techniques, Physics in Medicine and Biology, vol.56, issue.5, pp.1281-1298, 2011.
DOI : 10.1088/0031-9155/56/5/004

J. Campbell, C. Wong, O. Muzik, B. Marples, M. Joiner et al., Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission Tomography, International Journal of Radiation Oncology*Biology*Physics, vol.74, issue.1, pp.313-320, 2009.
DOI : 10.1016/j.ijrobp.2008.12.058

S. Stute, D. Benoit, A. Martineau, and N. Rehfeld, A method for accurate modelling of the crystal response function at a crystal sub-level applied to PET reconstruction, Physics in Medicine and Biology, vol.56, issue.3, pp.793-809, 2011.
DOI : 10.1088/0031-9155/56/3/016

C. Watson, Extension of Single Scatter Simulation to Scatter Correction of Time-of-Flight PET, IEEE Transactions on Nuclear Science, vol.54, issue.5, pp.1679-1686, 2007.
DOI : 10.1109/TNS.2007.901227