Skip to Main content Skip to Navigation
Journal articles

Early postsurgical visualization of composite mesh used in ventral hernia repair by amide proton transfer MRI.: Composite Mesh Visualization by APT MRI

Abstract : PURPOSE: The feasibility of noninvasive visualization of composite meshes used in ventral hernia repair by amide-proton transfer magnetic resonance imaging (APT-MRI) was explored. METHODS: Magnetization transfer asymmetry ratio images of composite meshes were obtained in vitro and in vivo from fast-spin echo acquisitions with frequency saturation offsets of ±3.5 ppm with respect to water frequency and no saturation. Three rats were assessed with APT-MRI each week for 1 month after the intraperitoneal implantation of two meshes, one on each side of the incision. One mesh was coated with collagen and the other was not. RESULTS: In vitro, meshes were delineated with APT-MRI as a thin continuous linear hypersignal located on one side of the mesh. Unlike collagen-free meshes, collagen-coated meshes were easily identified in vivo with APT-MRI during the first 3 weeks postimplantation. The composite meshes magnetization transfer asymmetry ratio (8.7 ± 2.8%) were significantly different from the muscle magnetization transfer asymmetry ratio value (-0.9 ± 1.6%). After a month, the mesh value dropped down to 1.1 ± 3.9%. Muscle and mesh magnetization transfer asymmetry ratio values were not significantly different and mesh conspicuity was no longer possible. CONCLUSION: The results suggest that APT-MRI is a promising technique for noninvasive, early postsurgical visualization of composite meshes used in ventral hernia repair. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.
Complete list of metadatas

Cited literature [17 references]  Display  Hide  Download

https://www.hal.inserm.fr/inserm-00793045
Contributor : Laurent Lemaire <>
Submitted on : Thursday, February 21, 2013 - 2:34:14 PM
Last modification on : Sunday, May 24, 2020 - 2:18:04 AM
Long-term archiving on: : Sunday, April 2, 2017 - 3:35:04 AM

File

 Restricted access
To satisfy the distribution rights of the publisher, the document is embargoed until : jamais

Please log in to resquest access to the document

Identifiers

Citation

Florence Franconi, Jérôme Roux, Xavier Garric, Laurent Lemaire. Early postsurgical visualization of composite mesh used in ventral hernia repair by amide proton transfer MRI.: Composite Mesh Visualization by APT MRI. Magnetic Resonance in Medicine, Wiley, 2014, epub ahead of print. ⟨10.1002/mrm.24666⟩. ⟨inserm-00793045⟩

Share

Metrics

Record views

786