PET functional volume delineation: a robustness and repeatability study.: Robustness of functional volume determination in PET

Abstract : PURPOSE: Current state-of-the-art algorithms for functional uptake volume segmentation in PET imaging consist of threshold-based approaches, whose parameters often require specific optimization for a given scanner and associated reconstruction algorithms. Different advanced image segmentation approaches previously proposed and extensively validated, such as among others fuzzy C-means (FCM) clustering, or fuzzy locally adaptive bayesian (FLAB) algorithm have the potential to improve the robustness of functional uptake volume measurements. The objective of this study was to investigate robustness and repeatability with respect to various scanner models, reconstruction algorithms and acquisition conditions. METHODS AND MATERIALS: Robustness was evaluated using a series of IEC phantom acquisitions carried out on different PET/CT scanners (Philips Gemini and Gemini Time-of-Flight, Siemens Biograph and GE Discovery LS) with their associated reconstruction algorithms (RAMLA, TF MLEM, OSEM). A range of acquisition parameters (contrast, duration) and reconstruction parameters (voxel size) were considered for each scanner model, and the repeatability of each method was evaluated on simulated and clinical tumours and compared to manual delineation. RESULTS: For all the scanner models, acquisition parameters and reconstruction algorithms considered, the FLAB algorithm demonstrated higher robustness in delineation of the spheres with low mean errors (10%) and variability (5%), with respect to threshold-based methodologies and FCM. The repeatability provided by all segmentation algorithms considered was very high with a negligible variability of <5% in comparison to that associated with manual delineation (5-35%). CONCLUSION: The use of advanced image segmentation algorithms may not only allow high accuracy as previously demonstrated, but also provide a robust and repeatable tool to aid physicians as an initial guess in determining functional volumes in PET.
Document type :
Journal articles
Complete list of metadatas

Cited literature [9 references]  Display  Hide  Download

https://www.hal.inserm.fr/inserm-00574273
Contributor : Mathieu Hatt <>
Submitted on : Friday, July 22, 2011 - 4:40:38 PM
Last modification on : Wednesday, June 24, 2020 - 4:18:09 PM
Long-term archiving on: : Friday, November 4, 2011 - 3:00:24 PM

File

EJNM_robustness.pdf
Files produced by the author(s)

Identifiers

Citation

Mathieu Hatt, Catherine Cheze Le Rest, Nidal Albarghach, Olivier Pradier, Dimitris Visvikis. PET functional volume delineation: a robustness and repeatability study.: Robustness of functional volume determination in PET. European Journal of Nuclear Medicine and Molecular Imaging, Springer Verlag (Germany), 2011, 38 (4), pp.663-72. ⟨10.1007/s00259-010-1688-6⟩. ⟨inserm-00574273⟩

Share

Metrics

Record views

1146

Files downloads

769