Accurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications.: Automatic PET image segmentation for oncology applications

Abstract : PURPOSE: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. METHODS AND MATERIALS: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. RESULTS: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T(bckg)) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +/- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +/- 11%. T(bckg) and FCM led to mean errors of 20% +/- 12% and 17% +/- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T(bckg) and FCM lead to 10%, 12%, and 13%, respectively. CONCLUSION: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.
Type de document :
Article dans une revue
International Journal of Radiation Oncology - Biology - Physics, Elsevier, 2010, 77 (1), pp.301-8. 〈10.1016/j.ijrobp.2009.08.018〉
Liste complète des métadonnées

Littérature citée [39 références]  Voir  Masquer  Télécharger

http://www.hal.inserm.fr/inserm-00537776
Contributeur : Mathieu Hatt <>
Soumis le : vendredi 19 novembre 2010 - 12:09:22
Dernière modification le : jeudi 20 septembre 2018 - 15:03:21
Document(s) archivé(s) le : dimanche 20 février 2011 - 02:52:18

Fichier

IJROBP2010_postproof.pdf
Fichiers produits par l'(les) auteur(s)

Identifiants

Collections

Citation

Mathieu Hatt, Catherine Cheze Le Rest, Patrice Descourt, André Dekker, Dirk De Ruysscher, et al.. Accurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications.: Automatic PET image segmentation for oncology applications. International Journal of Radiation Oncology - Biology - Physics, Elsevier, 2010, 77 (1), pp.301-8. 〈10.1016/j.ijrobp.2009.08.018〉. 〈inserm-00537776〉

Partager

Métriques

Consultations de la notice

293

Téléchargements de fichiers

422