Patterns of cortical discharges and their relation to routine scalp electroencephalography, Electroencephalography and Clinical Neurophysiology, vol.10, issue.3, pp.447-61, 1958. ,
DOI : 10.1016/0013-4694(58)90006-3
Intracerebral propagation of interictal activity in partial epilepsy: implications for source localisation., Journal of Neurology, Neurosurgery & Psychiatry, vol.57, issue.4, 1994. ,
DOI : 10.1136/jnnp.57.4.435
Lateralizing and localizing values of ictal onset recorded on the scalp: evidence from simultaneous recordings with intracranial foramen ovale electrodes, Epilepsia, vol.42, issue.11, pp.1426-1463, 2001. ,
Biomagnetic Source Detection by Maximum Entropy and Graphical Models, IEEE Transactions on Biomedical Engineering, vol.51, issue.3, pp.427-469, 2004. ,
DOI : 10.1109/TBME.2003.820999
A Bayesian approach to introducing anatomo-functional priors in the EEG/MEG inverse problem, IEEE Transactions on Biomedical Engineering, vol.44, issue.5, pp.374-85, 1997. ,
DOI : 10.1109/10.568913
Comparison of subcortical, cortical and scalp activity using chronically indwelling electrodes in man, Electroencephalography and Clinical Neurophysiology, vol.18, issue.3, pp.217-245, 1965. ,
DOI : 10.1016/0013-4694(65)90088-X
A Physiologically Plausible Spatio-Temporal Model for EEG Signals Recorded With Intracerebral Electrodes in Human Partial Epilepsy, IEEE Transactions on Biomedical Engineering, vol.54, issue.3, pp.380-388, 2007. ,
DOI : 10.1109/TBME.2006.890489
Improved Localizadon of Cortical Activity by Combining EEG and MEG with MRI Cortical Surface Reconstruction: A Linear Approach, Journal of Cognitive Neuroscience, vol.14, issue.2, pp.162-76, 1993. ,
DOI : 10.1007/BF02442317
Bayesian Spatio-Temporal Approach for EEG Source Reconstruction: Conciliating ECD and Distributed Models, IEEE Transactions on Biomedical Engineering, vol.53, issue.3, pp.503-519, 2006. ,
DOI : 10.1109/TBME.2005.869791
URL : https://hal.archives-ouvertes.fr/inserm-00163965
Defining Epileptogenic Foci: Past, Present, Future, Journal of Clinical Neurophysiology, vol.14, issue.6, pp.470-83, 1997. ,
DOI : 10.1097/00004691-199711000-00003
Models of the dynamics of neural populations, Electroencephalogr. Clin, 1978. ,
Electric Source Imaging in Temporal Lobe Epilepsy, Journal of Clinical Neurophysiology, vol.21, issue.4, pp.267-82, 2004. ,
DOI : 10.1097/01.WNP.0000139929.06455.82
The surface EEG in relation to its sources, Electroencephalography and Clinical Neurophysiology, vol.13, issue.6, 1961. ,
DOI : 10.1016/0013-4694(61)90199-7
Neuronal Generators and the Problem of Localization in Electroencephalography, Journal of Clinical Neurophysiology, vol.2, issue.4, pp.327-54, 1985. ,
DOI : 10.1097/00004691-198510000-00002
In vivo measurement of the brain and skull resistivities using an eit-based method and realistic models for the head, IEEE Transactions on Biomedical Engineering, vol.50, issue.6, pp.754-67, 2003. ,
DOI : 10.1109/TBME.2003.812164
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm, Electroencephalography and Clinical Neurophysiology, vol.95, issue.4, pp.231-51, 1995. ,
DOI : 10.1016/0013-4694(95)00107-A
Interpreting magnetic fields of the brain: minimum norm estimates, Medical & Biological Engineering & Computing, vol.22, issue.1, pp.35-42, 1994. ,
DOI : 10.1007/BF02512476
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data, IEEE Transactions on Biomedical Engineering, vol.36, issue.2, pp.165-71, 1989. ,
DOI : 10.1109/10.16463
Electroencephalogram and visual evoked potential generation in a mathematical model of coupled cortical columns, Biological Cybernetics, vol.580, issue.4, pp.357-66, 1995. ,
DOI : 10.1007/BF00199471
Dipole Modeling of Epileptic Spikes Can Be Accurate or Misleading, Epilepsia, vol.57, issue.3, pp.397-408, 2005. ,
DOI : 10.1097/00004691-200107000-00002
Dipole reconstruction as a method for identifying patients with mesolimbic epilepsy, Seizure, vol.6, issue.4, pp.303-313, 1997. ,
DOI : 10.1016/S1059-1311(97)80078-7
Models of Neuronal Populations: The Basic Mechanisms of Rhythmicity, Prog. Brain Res, vol.45, pp.281-308, 1976. ,
DOI : 10.1016/S0079-6123(08)60995-4
On the numerical accuracy of the boundary element method, IEEE Trans. Biomed. Eng, issue.10, pp.36-1038, 1989. ,
Topographical reliability of mesio-temporal sources of interictal spikes in temporal lobe epilepsy, Electroencephalography and Clinical Neurophysiology, vol.107, issue.3, 1998. ,
DOI : 10.1016/S0013-4694(98)00055-8
Reliability of dipole models of epileptic spikes, Clinical Neurophysiology, vol.110, issue.6, pp.1013-1041, 1999. ,
DOI : 10.1016/S1388-2457(98)00062-5
Spike-Wave Complexes and Fast Components of Cortically Generated Seizures. III. Synchronizing Mechanisms, J. Neurophysiol, vol.80, pp.1480-1494, 1998. ,
Low resolution electromagnetic tomography: a new method for localizing electrical activity in the brain, International Journal of Psychophysiology, vol.18, issue.1, pp.49-65, 1994. ,
DOI : 10.1016/0167-8760(84)90014-X
Considerations of quasi-stationarity in electrophysiological systems, The Bulletin of Mathematical Biophysics, vol.65, issue.4, pp.657-64, 1967. ,
DOI : 10.1007/BF02476917
Dynamics of non-convulsive epileptic phenomena modeled by a bistable neuronal network, Neuroscience, vol.126, issue.2, pp.467-84, 2004. ,
DOI : 10.1016/j.neuroscience.2004.03.014
Some Insights Into Computational Models of (Patho)physiological Brain Activity, Proc. IEEE, pp.784-804, 2006. ,
DOI : 10.1109/JPROC.2006.871773
Intracranial EEG Substrates of Scalp EEG Interictal Spikes, Epilepsia, vol.60, issue.5, pp.669-76, 2005. ,
DOI : 10.1023/A:1012944913650
The Impact of Cerebral Source Area and Synchrony on Recording Scalp Electroencephalography Ictal Patterns, Epilepsia, vol.35, issue.11, pp.2167-76, 2007. ,
DOI : 10.1111/j.1528-1157.2000.tb01535.x
Cortical Substrates of Scalp EEG Epileptiform Discharges, Journal of Clinical Neurophysiology, vol.24, issue.2, pp.96-100, 2007. ,
DOI : 10.1097/WNP.0b013e31803ecdaf
Neocortical pyramidal cells: a model with dendritic calcium conductance reproduces repetitive firing and epileptic behavior, Brain Research, vol.173, issue.2, pp.243-57, 1979. ,
DOI : 10.1016/0006-8993(79)90625-5
Fast Oscillations in Cortical Circuits, International Journal of Neural Systems, vol.10, issue.2, 1999. ,
DOI : 10.1016/S0129-0657(00)00013-2
Relevance of nonlinear lumped-parameter models in the analysis of depth-EEG epileptic signals, Biological Cybernetics, vol.83, issue.4, pp.367-78, 2000. ,
DOI : 10.1007/s004220000160
Interictal to ictal transition in human temporal lobe epilepsy: insights from a computational model of intracerebral EEG, 2005. ,
URL : https://hal.archives-ouvertes.fr/inserm-00147326
Transition to Ictal Activity in Temporal Lobe Epilepsy, Computational neuroscience in epilepsy, 2008. ,
DOI : 10.1016/B978-012373649-9.50026-0
Excitatory and Inhibitory Interactions in Localized Populations of Model Neurons, Biophysical Journal, vol.12, issue.1, pp.1-24, 1972. ,
DOI : 10.1016/S0006-3495(72)86068-5
Individually shaped volume conductor models of the head in EEG source localisation, Medical & Biological Engineering & Computing, vol.39, issue.2, pp.582-590, 1995. ,
DOI : 10.1007/BF02522518