G. Wu, ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion???Part II: shoulder, elbow, wrist and hand, Journal of Biomechanics, vol.38, issue.5, pp.981-992, 2005.
DOI : 10.1016/j.jbiomech.2004.05.042

T. P. Andriacchi, E. J. Alexander, M. K. Toney, C. Dyrby, and J. Sum, A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics, Journal of Biomechanical Engineering, vol.120, issue.6, pp.743-749, 1998.
DOI : 10.1115/1.2834888

T. Cresson, J. J. Jacq, V. Burdin, and C. Roux, Performing Accurate Rigid Kinematics Measurements from 3D in vivo Image Sequences through Median Consensus Simultaneous Registration, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, 2005.
DOI : 10.1109/IEMBS.2005.1616290

URL : https://hal.archives-ouvertes.fr/hal-00855619

C. Högfors, B. Peterson, G. Sigholm, and P. Herberts, Biomechanical model of the human shoulder joint???II. The shoulder rhythm, Journal of Biomechanics, vol.24, issue.8, pp.699-709, 1991.
DOI : 10.1016/0021-9290(91)90334-J

J. H. De-groot, The variability of shoulder motions recorded by means of palpation, Clinical Biomechanics, vol.12, issue.7-8, pp.461-472, 1997.
DOI : 10.1016/S0268-0033(97)00031-4

C. F. Beaulieu, Glenohumeral Relationships during Physiologic Shoulder Motion and Stress Testing: Initial Experience with Open MR Imaging and Active Imaging-Plane Registration, Radiology, vol.212, issue.3, pp.699-705, 1999.
DOI : 10.1148/radiology.212.3.r99se31699

R. C. Rhoad, A new in vivo technique for three-dimensional shoulder kinematics analysis, Skeletal Radiology, vol.27, issue.2, pp.92-97, 1998.
DOI : 10.1007/s002560050344

S. S. Rao, E. L. Bontrager, J. K. Gronley, C. J. Newsam, and J. Perry, Three-dimensional kinematics of wheelchair propulsion, IEEE Transactions on Rehabilitation Engineering, vol.4, issue.3, pp.152-160, 1996.
DOI : 10.1109/86.536770

C. G. Meskers, H. Fraterman, F. C. Van-der-helm, H. M. Vermeulen, and P. M. Rozing, Calibration of the ???Flock of Birds??? electromagnetic tracking device and its application in shoulder motion studies, Journal of Biomechanics, vol.32, issue.6, pp.629-633, 1999.
DOI : 10.1016/S0021-9290(99)00011-1

K. Matsui, K. Shimada, and P. Andrew, Deviation of skin marker from bone target during movement of the scapula, Journal of Orthopaedic Science, vol.11, issue.2, pp.180-184, 2006.
DOI : 10.1007/s00776-005-1000-y

J. R. Williams, Some aspects of the biomechanics of the elbow joint related to prosthetic design, 1996.

A. Leardini, L. Chiari, U. D. Croce, and A. Cappozzo, Human movement analysis using stereophotogrammetry, Gait & Posture, vol.21, issue.2, pp.212-225, 2005.
DOI : 10.1016/j.gaitpost.2004.05.002

F. E. Veldpaus, H. J. Woltring, and L. J. Dortmans, A least-squares algorithm for the equiform transformation from spatial marker co-ordinates, Journal of Biomechanics, vol.21, issue.1, pp.45-55, 1988.
DOI : 10.1016/0021-9290(88)90190-X

I. Soderkvist and P. Wedin, Determining the movements of the skeleton using well-configured markers, Journal of Biomechanics, vol.26, issue.12, pp.1473-1477, 1993.
DOI : 10.1016/0021-9290(93)90098-Y

L. Chèze, B. J. Fregly, and J. Dimnet, A solidification procedure to facilitate kinematic analyses based on video system data, Journal of Biomechanics, vol.28, issue.7, pp.879-884, 1995.
DOI : 10.1016/0021-9290(95)95278-D

T. W. Lu and J. J. Connor, Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints, Journal of Biomechanics, vol.32, issue.2, pp.129-134, 1999.
DOI : 10.1016/S0021-9290(98)00158-4

E. Roux, S. Bouilland, A. Godillon-maquinghen, and D. Bouttens, Evaluation of the global optimisation method within the upper limb kinematics analysis, Journal of Biomechanics, vol.35, issue.9, pp.1279-1283, 2002.
DOI : 10.1016/S0021-9290(02)00088-X

URL : https://hal.archives-ouvertes.fr/hal-00396044

E. J. Alexander and T. P. Andriacchi, Correcting for deformation in skin-based marker systems, Journal of Biomechanics, vol.34, issue.3, pp.355-361, 2001.
DOI : 10.1016/S0021-9290(00)00192-5

C. Schwartz, M. Lempereur, V. Burdin, J. J. Jacq, and O. Rémy-néris, Méthode d'analyse du mouvement par utilisation de nappes de marqueurs, TAIMA Conference, 2007.

J. J. Jacq, Performing Accurate Joint Kinematics from 3D in vivo Image Sequences through Median Consensus Simultaneous Registration, 2005.

J. J. Jacq, T. Cresson, V. Burdin, and C. Roux, Performing Accurate Joint Kinematics from 3D in vivo Image Sequences through Consensus- Driven Simultaneous Registration, IEEE Trans. on Biomedical Engineering
URL : https://hal.archives-ouvertes.fr/hal-00855168

P. W. Mcclure, L. A. Michener, and B. J. Sennett, Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo, Journal of Shoulder and Elbow Surgery, vol.10, issue.3, pp.269-77, 2001.
DOI : 10.1067/mse.2001.112954