Production of Focal Destructive Lesions in the Central Nervous System With Ultrasound, Journal of Neurosurgery, vol.11, issue.5, pp.471-479, 1954. ,
DOI : 10.3171/jns.1954.11.5.0471
Transrectal High Intensity Focused Ultrasound for the Treatment of Localized Prostate Cancer: Factors Influencing the Outcome, European Urology, vol.40, issue.2, pp.124-133, 2001. ,
DOI : 10.1159/000049761
Transrectal high-intensity focused ultrasound for treatment of patients with stage T1b-2n0m0 localized prostate cancer: a preliminary report, Urology, vol.59, issue.3, pp.394-402, 2002. ,
DOI : 10.1016/S0090-4295(01)01624-7
MR Imaging???guided Focused Ultrasound Surgery of Uterine Leiomyomas: A Feasibility Study, Radiology, vol.226, issue.3, pp.897-905, 2003. ,
DOI : 10.1148/radiol.2271020395
Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: an overview, Ultrasonics Sonochemistry, vol.11, issue.3-4, pp.3-4149, 2004. ,
DOI : 10.1016/j.ultsonch.2004.01.011
The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population, British Journal of Cancer, vol.236, issue.8, pp.890-895, 2005. ,
DOI : 10.1016/0022-3468(92)90321-W
The feasibility of interstitial ultrasound hyperthermia, Medical Physics, vol.19, issue.4, pp.979-87, 1992. ,
DOI : 10.1118/1.596786
Percutaneous radiofrequency ablation for hepatocellular carcinoma, Cancer, vol.29, issue.6, pp.1201-1210, 2005. ,
DOI : 10.1002/cncr.20892
MR-guided laser-induced thermotherapy (LITT) of liver tumours: experimental and clinical data, International Journal of Hyperthermia, vol.229, issue.7, pp.713-737, 2004. ,
DOI : 10.1148/radiology.209.2.9807562
Combination of neoadjuvant chemotherapy with cryotherapy and surgical resection for the treatment of unresectable liver metastases from colorectal carcinoma, Cancer, vol.135, issue.11, pp.2283-92, 2002. ,
DOI : 10.1002/cncr.10973
Hyperthermia--its actual role in radiation oncology. Part IV: Thermo-radiotherapy for malignant brain tumors, Strahlenther Onkol, vol.171, issue.10, pp.560-72, 1995. ,
Control of interstitial thermal coagulation: Comparative evaluation of microwave and ultrasound applicators, Medical Physics, vol.175, issue.1, pp.104-121, 2001. ,
DOI : 10.1118/1.1334606
Axial control of thermal coagulation using a multielement intestitial ultrasound applicator with internal cooling, IEEE Trans. Ultrason. Ferroelec. Freq. Contr, vol.47, issue.1, pp.1541-1545, 2000. ,
Miniaturized ultrasound arrays for interstitial ablation and imaging, Ultrasound in Medicine & Biology, vol.31, issue.11, pp.1539-50, 2005. ,
DOI : 10.1016/j.ultrasmedbio.2005.07.008
3-D real-time motion correction in high-intensity focused ultrasound therapy, Ultrasound in Medicine & Biology, vol.30, issue.9, pp.1239-1288, 2004. ,
DOI : 10.1016/j.ultrasmedbio.2004.07.021
URL : https://hal.archives-ouvertes.fr/inserm-00468901
Design and preliminary results of an ultrasound applicator for interstitial thermal coagulation, Ultrasound in Medicine & Biology, vol.24, issue.1, pp.113-135, 1998. ,
DOI : 10.1016/S0301-5629(97)00203-2
Multifrequency ultrasound transducers for conformal interstitial thermal therapy, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.50, issue.7, pp.881-890, 2003. ,
DOI : 10.1109/TUFFC.2003.1214507
MRI-guided interstitial ultrasound thermal therapy of the prostate: A feasibility study in the canine model, Medical Physics, vol.31, issue.3, pp.733-776, 2005. ,
DOI : 10.1118/1.1861163
Optimizing the shape of ultrasound transducers for interstitial thermal ablation, Medical Physics, vol.12, issue.3, pp.290-297, 2002. ,
DOI : 10.1118/1.1445416
Curvilinear transurethral ultrasound applicator for selective prostate thermal therapy, Medical Physics, vol.30, issue.4, pp.1555-65, 2005. ,
DOI : 10.1016/j.ultrasmedbio.2003.11.016
Cancer treatment by ultrasound: Increasing the depth of necrosis, Applied Physics Letters, vol.84, issue.26, pp.5365-5367, 2004. ,
DOI : 10.1063/1.1767277
Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein, Journal of Interventional Cardiac Electrophysiology, vol.8, issue.2, pp.141-149, 2003. ,
DOI : 10.1023/A:1023613018185
Directional power deposition from direct-coupled and catheter-cooled interstitial ultrasound applicators, International Journal of Hyperthermia, vol.20, issue.2, pp.129-173, 2000. ,
DOI : 10.1080/026567300285330
Ultrasound cylindrical phased array for transoesophageal thermal therapy: initial studies, Physics in Medicine and Biology, vol.47, issue.23, pp.4191-203, 2002. ,
DOI : 10.1088/0031-9155/47/23/306
Catheter Ultrasound Phased-Array Transducers for Thermal Ablation: A Feasibility Study, Ultrasonic Imaging, vol.39, issue.2, pp.89-100, 2005. ,
DOI : 10.1177/016173460502700203
The development of intracavitary ultrasonic applicators for hyperthermia: A design and experimental study, Medical Physics, vol.17, issue.4, pp.626-660, 1990. ,
DOI : 10.1118/1.596582
Cylindrical ultrasonic transducers for cardiac catheter ablation, IEEE Transactions on Biomedical Engineering, vol.44, issue.2, pp.144-51, 1997. ,
DOI : 10.1109/10.552244
Air-cooling of direct-coupled ultrasound applicators for interstitial hyperthermia and thermal coagulation, Medical Physics, vol.7, issue.12, pp.2400-2409, 1998. ,
DOI : 10.1118/1.598451
Theoretical comparison of two interstitial ultrasound applicators designed to induce cylindrical zones of tissue ablation, Medical & Biological Engineering & Computing, vol.10, issue.5, pp.298-303, 1999. ,
DOI : 10.1007/BF02513303
The feasibility of using ultrasound for cardiac ablation, IEEE Transactions on Biomedical Engineering, vol.42, issue.9, pp.891-898, 1995. ,
DOI : 10.1109/10.412655
Destruction of a bile duct carcinoma by intraductal high intensity ultrasound during ERCP, Gastrointestinal Endoscopy, vol.53, issue.7, pp.797-800, 2001. ,
DOI : 10.1067/mge.2001.112713
Feasibility of linear arrays for interstitial ultrasound thermal therapy, Medical Physics, vol.3, issue.6, pp.1281-1287, 2000. ,
DOI : 10.1118/1.599006
Effects of spatial and temporal resolution for MR image-guided thermal ablation of prostate with transurethral ultrasound, Journal of Magnetic Resonance Imaging, vol.41, issue.1, pp.109-127, 2005. ,
DOI : 10.1002/jmri.20339
Therapeutic endoscopy and endoscopic ultrasound for gastrointestinal malignancies, Expert Review of Anticancer Therapy, vol.5, issue.4, pp.705-723, 2005. ,
DOI : 10.1586/14737140.5.4.705
Development of an interstitial ultrasound applicator for endoscopic procedures: animal experimentation, Ultrasound in Medicine & Biology, vol.26, issue.4, pp.669-75, 2000. ,
DOI : 10.1016/S0301-5629(99)00157-X
study, Medical Physics, vol.41, issue.8, pp.2926-2934, 2006. ,
DOI : 10.1002/(SICI)1522-2594(199902)41:2<321::AID-MRM16>3.0.CO;2-9
URL : https://hal.archives-ouvertes.fr/inserm-00192601
Transoesophageal ultrasound applicator for sector-based thermal ablation: first in vivo experiments, Ultrasound in Medicine & Biology, vol.29, issue.2, pp.285-91, 2003. ,
DOI : 10.1016/S0301-5629(02)00701-9
URL : https://hal.archives-ouvertes.fr/inserm-00000048
Multisectored interstitial ultrasound applicators for dynamic angular control of thermal therapy, Medical Physics, vol.50, issue.5, pp.1352-63, 2006. ,
DOI : 10.1109/TUFFC.2003.1214507
Evaluation of multielement catheter-cooled interstitial ultrasound applicators for high-temperature thermal therapy, Medical Physics, vol.64, issue.7, pp.1525-1559, 2001. ,
DOI : 10.1118/1.1381550
Using Intraductal ultrasound for the treatment of digestive tumours: First clinical results, Proceedings of the 3rd International Symposium on Therapeutic Ultrasound, pp.145-150, 2003. ,
Feasibility of ultrasound hyperthermia with waveguide interstitial applicator, IEEE Transactions on Biomedical Engineering, vol.43, issue.11, pp.1106-1121, 1996. ,
DOI : 10.1109/10.541252
Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh, Magnetic Resonance in Medicine, vol.196, issue.Suppl 1, pp.89-98, 2003. ,
DOI : 10.1002/mrm.10328
study, Medical Physics, vol.50, issue.2, pp.236-280, 2004. ,
DOI : 10.1118/1.1634909
URL : https://hal.archives-ouvertes.fr/inserm-00192601
Intraluminal high intensity ultrasound treatment in the esophagus under fast MR temperature mapping: In vivo studies, Magnetic Resonance in Medicine, vol.23, issue.4, pp.975-82, 2005. ,
DOI : 10.1002/mrm.20638
500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls, Magnetic Resonance in Medicine, vol.64, issue.1, pp.100-107, 2004. ,
DOI : 10.1002/mrm.20118
Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback, Physics in Medicine and Biology, vol.51, issue.4, pp.827-871, 2006. ,
DOI : 10.1088/0031-9155/51/4/005
Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators, Physics in Medicine and Biology, vol.50, issue.21, pp.4957-75, 2005. ,
DOI : 10.1088/0031-9155/50/21/001
Multiplanar MR temperature-sensitive imaging of cerebral thermal treatment using interstitial ultrasound applicators in a canine model, Journal of Magnetic Resonance Imaging, vol.196, issue.5, pp.522-553, 2002. ,
DOI : 10.1002/jmri.10191
Real time inverse filter focusing through iterative time reversal, The Journal of the Acoustical Society of America, vol.115, issue.2, pp.768-75, 2004. ,
DOI : 10.1121/1.1636462
Temperature estimation using ultrasonic spatial compound imaging, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.51, issue.5, pp.606-621, 2004. ,
DOI : 10.1109/TUFFC.2004.1320832
Elastography, Comptes Rendus de l'Acad??mie des Sciences - Series IV - Physics, vol.2, issue.8, pp.111-34401, 1991. ,
DOI : 10.1016/S1296-2147(01)01255-0
Monitoring the formation of thermal lesions with heat-induced echo-strain imaging: A feasibility study, Ultrasound in Medicine & Biology, vol.31, issue.2, pp.251-260, 2005. ,
DOI : 10.1016/j.ultrasmedbio.2004.11.004
Finite-element analysis of temperature rise and lesion formation from catheter ultrasound ablation transducers, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.52, issue.10, pp.1713-1734, 2005. ,
DOI : 10.1109/TUFFC.2005.1561625
Control of Prostate Cancer by Transrectal HIFU in 227 Patients Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate, Eur Urol Int J Hyperthermia, vol.5620, issue.7, pp.739-56, 2004. ,
Transurethral ultrasound array for prostate thermal therapy: initial studies, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.43, issue.6, pp.1011-1033, 1996. ,
DOI : 10.1109/58.542046
Combination of transurethral and interstitial ultrasound applicators for high-temperature prostate thermal therapy, International Journal of Hyperthermia, vol.140, issue.5, pp.385-403, 2000. ,
DOI : 10.1080/026567300416695
Feasibility of using interstitial ultrasound for intradiscal thermal therapy: a study in human cadaver lumbar discs, Physics in Medicine and Biology, vol.50, issue.12, pp.2807-2828, 2005. ,
DOI : 10.1088/0031-9155/50/12/006
evaluation using magnetic resonance thermometry, Medical Physics, vol.29, issue.2, pp.405-418, 2004. ,
DOI : 10.1118/1.1639959
Small cylindrical ultrasound sources for induction of hyperthermia via body cavities or interstitial implants, International Journal of Hyperthermia, vol.15, issue.2, pp.263-74, 1993. ,
DOI : 10.3109/02656739309022539
Effects of physical parameters on high temperature ultrasound hyperthermia, Ultrasound in Medicine & Biology, vol.16, issue.4, pp.409-420, 1990. ,
DOI : 10.1016/0301-5629(90)90070-S
Interstitial ultrasound heating applicator for MR-guided thermal therapy, Physics in Medicine and Biology, vol.46, issue.12, pp.3133-3178, 2001. ,
DOI : 10.1088/0031-9155/46/12/305
A study of various parameters of spherically curved phased arrays for noninvasive ultrasound surgery, Physics in Medicine and Biology, vol.41, issue.4, pp.591-608, 1996. ,
DOI : 10.1088/0031-9155/41/4/002
Sparse random ultrasound phased array for focal surgery, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.43, issue.6, pp.1111-1121, 1996. ,
DOI : 10.1109/58.542054
First Human Experience With Pulmonary Vein Isolation Using a Through-the-Balloon Circumferential Ultrasound Ablation System for Recurrent Atrial Fibrillation, Circulation, vol.102, issue.16, pp.1879-82, 2000. ,
DOI : 10.1161/01.CIR.102.16.1879
Feasibility of a transurethral ultrasound applicator for coagulation in prostate, Ultrasound in Medicine & Biology, vol.30, issue.1, pp.113-135, 2004. ,
DOI : 10.1016/j.ultrasmedbio.2003.10.009