M. Devous, R. Thisted, G. Morgan, R. Leroy, and C. Rowe, SPECT brain imaging in epilepsy: a metaanalysis, J Nucl Med, vol.39, pp.285-293, 1998.

A. Baird, G. Donnan, M. Austin, O. Hennessy, J. Royle et al., Asymmetries of cerebral perfusion in a stroke-age population, Journal of Clinical Neuroscience, vol.6, issue.2, pp.113-120, 1999.
DOI : 10.1016/S0967-5868(99)90075-9

I. Kuji, H. Sumiya, and Y. Niida, Age-related changes in the cerebral distribution of 99mTc-ECD from infancy to adulthood, J Nucl Med, vol.40, pp.1818-1823, 1999.

O. Migneco, J. Darcourt, and J. Benoliel, Computerized localization of brain structures in single photon emission computed tomography using a proportional anatomical stereotactic atlas, Computerized Medical Imaging and Graphics, vol.18, issue.6, pp.413-422, 1994.
DOI : 10.1016/0895-6111(94)90078-7

I. Zubal, S. Spencer, K. Imam, J. Seibyl, E. Smith et al., Difference images calculated from ictal and interictal technetium-99m-HMPAO SPECT scans of epilepsy, J Nucl Med, vol.36, pp.684-689, 1995.

O. Brien, T. So, E. Mullan, and B. , Subtraction ictal SPECT co-registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus, Neurology, vol.50, issue.2, pp.445-454, 1998.
DOI : 10.1212/WNL.50.2.445

J. Lee, H. Kim, B. Lee, O. Kim, T. Jeon et al., Evaluation of ictal brain SPET using statistical parametric mapping in temporal lobe epilepsy, European Journal of Nuclear Medicine, vol.27, issue.11, pp.1658-1665, 2000.
DOI : 10.1007/s002590000364

B. Aubert-broche, C. Grova, and P. Jannin, Detection of inter-hemispheric asymmetries of brain perfusion in SPECT, Physics in Medicine and Biology, vol.48, issue.11, pp.1505-1517, 2003.
DOI : 10.1088/0031-9155/48/11/302

URL : https://hal.archives-ouvertes.fr/inserm-00333437

L. Barnden, R. Kwiatek, and Y. Lau, Validation of fully automatic brain SPET to MR co-registration, European Journal of Nuclear Medicine and Molecular Imaging, vol.27, issue.2, pp.147-154, 2000.
DOI : 10.1007/s002590050020

F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens, Multimodality image registration by maximization of mutual information, IEEE Transactions on Medical Imaging, vol.16, issue.2, pp.187-198, 1997.
DOI : 10.1109/42.563664

C. Studholme, D. Hill, and D. Hawkes, An overlap invariant entropy measure of 3D medical image alignment, Pattern Recognition, vol.32, issue.1
DOI : 10.1016/S0031-3203(98)00091-0

A. Roche, G. Malandain, X. Pennec, and N. Ayache, The correlation ratio as a new similarity measure for HAL author manuscript inserm-00136496, version 1 HAL author manuscript inserm-00136496

R. Woods, J. Mazziotta, and S. Cherry, MRI-PET Registration with Automated Algorithm, Journal of Computer Assisted Tomography, vol.17, issue.4, pp.536-546, 1993.
DOI : 10.1097/00004728-199307000-00004

C. Grova, P. Jannin, I. Buvat, H. Benali, and B. Gibaud, Evaluation of Registration of Ictal SPECT/MRI Data Using Statistical Similarity Methods, Lecture Notes in Computer Science, vol.3216, pp.687-695, 2004.
DOI : 10.1007/978-3-540-30135-6_84

K. Friston, J. Ashburner, J. Poline, C. Frith, J. Heather et al., Spatial registration and normalization of images, Human Brain Mapping, vol.16, issue.3, pp.165-189, 1995.
DOI : 10.1002/hbm.460030303

I. Zubal, C. Harrell, E. Smith, Z. Rattner, G. Gindi et al., Computerized three-dimensional segmented human anatomy, Medical Physics, vol.21, issue.2, pp.299-302, 1994.
DOI : 10.1118/1.597290

C. Grova, P. Jannin, and A. Biraben, A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy, Physics in Medicine and Biology, vol.48, issue.24, pp.4023-4043, 2003.
DOI : 10.1088/0031-9155/48/24/003

URL : https://hal.archives-ouvertes.fr/inserm-00332761

R. Huesman, G. Gullberg, W. Greenberg, and T. Budinger, RECLBL library users manual, Donner algorithms for reconstruction tomography, 1977.

S. Starr, C. Metz, L. Lusted, and D. Goodenough, Visual Detection and Localization of Radiographic Images, Radiology, vol.116, issue.3, pp.533-538, 1975.
DOI : 10.1148/116.3.533

L. Chang, A Method for Attenuation Correction in Radionuclide Computed Tomography, IEEE Transactions on Nuclear Science, vol.25, issue.1, pp.638-643, 1978.
DOI : 10.1109/TNS.1978.4329385

K. Kang, D. Lee, and J. Cho, Quantification of F-18 FDG PET Images in Temporal Lobe Epilepsy Patients Using Probabilistic Brain Atlas, NeuroImage, vol.14, issue.1, pp.1-6, 2001.
DOI : 10.1006/nimg.2001.0783

E. Stamatakis, J. Wilson, D. Hadley, and D. Wyper, Spect imaging in head injury interpreted with statistical parametric mapping, J Nucl Med, vol.43, pp.476-483, 2002.

K. Van-laere, J. Versijpt, and K. Audenauert, 99mTc-ECD brain perfusion SPET: variability, asymmetry and effects of age and gender in healthy adults, European Journal of Nuclear Medicine, vol.28, issue.7, pp.873-887, 2001.
DOI : 10.1007/s002590100549

P. Van-bogaert, N. Massager, and P. Tugendhaft, Statistical Parametric Mapping of Regional Glucose Metabolism in Mesial Temporal Lobe Epilepsy, NeuroImage, vol.12, issue.2, pp.129-138, 2000.
DOI : 10.1006/nimg.2000.0606