P. Jannin, X. Morandi, O. Fleig, E. Le-rumeur, P. Toulouse et al., Integration of sulcal and functional information for multimodal neuronavigation, Journal of Neurosurgery, vol.96, issue.4, pp.713-723, 2002.
DOI : 10.3171/jns.2002.96.4.0713

URL : https://hal.archives-ouvertes.fr/inserm-00331751

P. Jannin, O. Fleig, E. Seigneuret, C. Grova, X. Morandi et al., A Data Fusion Environment for Multimodal and Multi-Informational Neuronavigation, Computer Aided Surgery, vol.17, issue.3, pp.1-10, 2000.
DOI : 10.1016/S1361-8415(01)80004-9

URL : https://hal.archives-ouvertes.fr/inserm-00331756

O. Ganslandt, R. Fahlbusch, C. Nimsky, H. Kober, M. M. ¨-oller et al., Functional neuronavigation with magnetoencephalography: outcome in 50 patients with lesions around the motor cortex, J Neurosurg, issue.91, pp.73-79, 1999.

M. Schulder, J. Maldjian, W. Liu, A. Holodny, A. Kalnin et al., Functional image???guided surgery of intracranial tumors located in or near the sensorimotor cortex, Journal of Neurosurgery, vol.89, issue.3, pp.412-418, 1998.
DOI : 10.3171/jns.1998.89.3.0412

J. Luber and A. Mackevics, Multiple co-ordinate manipulator (mkm): A computer-assisted microscope, pp.1121-1125, 1995.

P. Edwards, A. King, C. J. Maurer, D. De-cunha, D. Hawkes et al., Design and evaluation of a system for microscope-assisted guided interventions (MAGI), IEEE Transactions on Medical Imaging, vol.19, issue.11, pp.1082-1093, 2000.
DOI : 10.1109/42.896784

C. Maurer, F. Sauer, B. Bascle, B. Geiger, F. Wenzel et al., Augmented reality visualization of brain structures with stereo and kinetic depth cues: System description and initial evaluation with head phantom, Visualization, Display, and Image- Guided Procedures Proc SPIE 4319, pp.445-456, 2001.

W. Grimson, G. Ettinger, S. White, T. Lozano-pérez, W. Wells et al., An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization, IEEE Transactions on Medical Imaging, vol.15, issue.2, pp.129-140, 1996.
DOI : 10.1109/42.491415

A. Colchester, J. Zhao, K. Holton-tainter, C. Henri, N. Maitland et al., Development and preliminary evaluation of VISLAN, a surgical planning and guidance system using intra-operative video imaging, Medical Image Analysis, vol.1, issue.1, pp.73-90, 1996.
DOI : 10.1016/S1361-8415(01)80006-2

M. Uenohara and T. Kanade, Vision-based object registration for real-time image overlay, Computers in Biology and Medicine, vol.25, issue.2, pp.249-260, 1995.
DOI : 10.1016/0010-4825(94)00045-R

P. Jannin, A. Bouliou, E. Journet, and J. Scarabin, A ray-traced texture mapping for enhanced virtuality in image-guided neurosurgery, Stud Health Technol Inform, vol.29, pp.553-563, 1996.
URL : https://hal.archives-ouvertes.fr/inserm-00333607

P. Jannin, A. Bouliou, J. Scarabin, C. Barillot, and J. Luber, <title>Visual matching between real and virtual images in image-guided neurosurgery</title>, Medical Imaging 1997: Image Display, pp.518-526, 1997.
DOI : 10.1117/12.273931

D. Dey, D. G. Gobbi, P. J. Slomka, K. J. Surry, and T. M. Peters, Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces: creating stereoscopic panoramas, IEEE Transactions on Medical Imaging, vol.21, issue.1, pp.23-30, 2002.
DOI : 10.1109/42.981231

R. Shahidi, M. Bax, C. J. Maurer, J. Johnson, E. Wilkinson et al., Implementation, calibration and accuracy testing of an image-enhanced endoscopy system, IEEE Transactions on Medical Imaging, vol.21, issue.12, pp.1424-1435, 2002.
DOI : 10.1109/TMI.2002.806597

O. Fleig, F. Devernay, J. Scarabin, and P. Jannin, Surface reconstruction of the surgical field from stereoscopic microscope views in neurosurgery, Proc. CARS'2001, pp.259-264, 2001.
DOI : 10.1016/S0531-5131(01)00054-1

URL : https://hal.archives-ouvertes.fr/hal-00816696

O. Skrinjar, H. Tagare, and J. Duncan, Surface growing from stereo images, Proceedings IEEE Conference on Computer Vision and Pattern Recognition. CVPR 2000 (Cat. No.PR00662), pp.571-576, 2000.
DOI : 10.1109/CVPR.2000.854920

H. Sun, H. Farid, K. Rick, A. Hartov, D. Roberts et al., Estimating Cortical Surface Motion Using Stereopsis for Brain Deformation Models, Proc. Medical Image Computing and Computer-Assisted Intervention MICCAI'03, pp.794-801, 2003.
DOI : 10.1007/978-3-540-39899-8_97

M. Audette, K. Siddiqi, and T. Peters, Level-Set Surface Segmentation and Fast Cortical Range Image Tracking for Computing Intrasurgical Deformations, Proc. Medical Image Computing and Computer-Assisted Intervention MICCAI'99, pp.788-797, 1999.
DOI : 10.1007/10704282_86

M. Miga, T. Sinha, D. Cash, R. Galloway, and R. Weil, Cortical surface registration for image-guided neurosurgery using laser-range scanning, IEEE Transactions on Medical Imaging, vol.22, issue.8, pp.973-985, 2003.
DOI : 10.1109/TMI.2003.815868

W. Schroeder, K. Martin, and B. Lorensen, The Visualization Toolkit An Object-Oriented Approach To 3D Graphics, 1993.

F. Devernay, Vision stéréoscopique et propriétés différentielles des surfaces, 1997.

R. Y. Tsai, A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses, IEEE Journal on Robotics and Automation, vol.3, issue.4, pp.323-344, 1987.
DOI : 10.1109/JRA.1987.1087109

F. Devernay and O. Faugeras, Computing differential properties of 3-D shapes from stereoscopic images without 3-D models, Proceedings of IEEE Conference on Computer Vision and Pattern Recognition CVPR-94, pp.208-213, 1994.
DOI : 10.1109/CVPR.1994.323831

URL : https://hal.archives-ouvertes.fr/inria-00074369

P. Paul, O. Fleig, S. Tranchant, and P. Jannin, Performance Evaluation of a Stereoscopic Based 3D Surface Localiser for Image-Guided Neurosurgery, MICCAI 04, 2004.
DOI : 10.1007/978-3-540-30136-3_63

P. Jannin, M. Fitzpatrick, D. Hawkes, X. Pennec, R. Shahidi et al., Validation of medical image processing in image-guided therapy, IEEE Transactions on Medical Imaging, vol.21, issue.12, pp.1445-1449, 2002.
DOI : 10.1109/TMI.2002.806568

URL : https://hal.archives-ouvertes.fr/inserm-00331766

J. Fitzpatrick, J. West, and C. Maurer, Predicting error in rigid-body point-based registration, IEEE Transactions on Medical Imaging, vol.17, issue.5, pp.694-702, 1998.
DOI : 10.1109/42.736021

C. Maurer, R. Maciunas, and J. Fitzpatrick, Registration of head CT images to physical space using a weighted combination of points and surfaces [image-guided surgery], IEEE Transactions on Medical Imaging, vol.17, issue.5, pp.753-761, 1998.
DOI : 10.1109/42.736031

C. Maurer, D. Hill, A. Martin, H. Liu, M. Mccue et al., Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results, IEEE Transactions on Medical Imaging, vol.17, issue.5, pp.817-825, 1998.
DOI : 10.1109/42.736050

T. Hartkens, D. Hill, A. Castellano-smith, C. Hawkes, A. Maurer et al., Measurement and analysis of brain deformation during neurosurgery, IEEE Transactions on Medical Imaging, vol.22, issue.1, pp.88-92, 2003.
DOI : 10.1109/TMI.2002.806596