G. T. Herman, Image Reconstruction From Projections, Real-Time Imaging, vol.1, issue.1, pp.3-18, 1995.
DOI : 10.1006/rtim.1995.1002

S. Chang, The reconstruction of binary patterns from their projections, Communications of the ACM, vol.14, issue.1, pp.21-25, 1971.
DOI : 10.1145/362452.362471

S. Chang and Y. Wang, Three-dimensional object reconstruction from orthogonal projections, Pattern Recognition, vol.7, issue.4, pp.167-176, 1975.
DOI : 10.1016/0031-3203(75)90002-3

S. K. Chang and C. K. Chow, The reconstruction of three-dimensional objects from two orthogonal projections and its application to cardiac cineangiography, IEEE Transactions on Computers, pp.18-28, 1973.

D. G. Onnasch and P. H. Heintzen, A new approach for the reconstruction of the right or left ventricular form from biplane angiography recordings, Proceedings of Computers in Cardiology, pp.67-73, 1976.

D. G. Onnasch, A concept for the approximate reconstruction of the form of the right or left ventricle from biplane angiograms, Roentgen-Video Techniques for dynamic studies of structure and function of the Heart and Circulation, P. H. Heintzel

H. Cornelis and J. J. Gerbrands, A network flow approach to reconstruction of the left ventricle from two projections, Computer Graphics and Image Processing, vol.18, pp.18-36, 1982.

Y. Wang, P. A. Heng, and F. M. Wahl, Image reconstructions from two orthogonal projections, International Journal of Imaging Systems and Technology, vol.11, issue.2, pp.141-145, 2003.
DOI : 10.1002/ima.10036

G. Prause and D. G. Onnasch, Binary reconstruction of the heart chambers from biplane angiographic image sequences, IEEE Transactions on Medical Imaging, vol.15, issue.4, pp.532-546, 1996.
DOI : 10.1109/42.511756

M. Moriyama, Y. Sato, H. Naito, M. Hanayama, T. Ueguchi et al., Reconstruction of time-varying 3-D left-ventricular shape from multiview X-ray cineangiocardiograms, IEEE Transactions on Medical Imaging, vol.21, issue.7, pp.773-785, 2002.
DOI : 10.1109/TMI.2002.801161

Y. Sato, M. Moriyama, M. Hanayama, H. Naito, and S. Tamura, Acquiring 3-D models of nonrigid moving objects from time and viewpoint varying image sequences: A step toward left ventricle recovery, IEEE Transactions on Pattern Analysis and Machine Intelligence, pp.253-258, 1997.

H. Kehl, J. Jäger, N. Papazis, D. Dimitrelos, J. Gehrmann et al., 3D heart modelling from biplane, rotational angiocardiographic X-ray sequences, Computers & Graphics, vol.24, issue.5, pp.731-739, 2000.
DOI : 10.1016/S0097-8493(00)00075-3

R. Medina, Reconstruction tridimensionnelle du ventricule gauche en angiographie bi-plan, Ph.D. dissertation, University of Rennes, vol.1, 1998.

R. Medina, M. Garreau, H. Lebreton, and D. Jugo, Three-dimensional reconstruction of the left ventricle from two angiographic views, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136), pp.569-572, 1997.
DOI : 10.1109/IEMBS.1997.757673

J. Toro, R. Medina, M. Garreau, D. Jugo, and H. Carrasco, Left ventricle 3D reconstruction using gibbs random fields and simulated annealing, Proceedings of the I International Seminar of Simulation and Modelling in Bioengineering, pp.239-248, 1996.

R. Medina, M. Garreau, J. Toro, J. L. Coatrieux, and D. Jugo, Three-Dimensional Reconstruction of the Left Ventricle From Two Angiographic Views: An Evidence Combination Approach, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans, vol.34, issue.3, pp.359-370, 2004.
DOI : 10.1109/TSMCA.2003.822265

R. Medina, M. Garreau, C. Navarro, J. Coatrieux, and D. Jugo, Reconstruction of the left ventricle shape from two angiographic views: a fuzzy and evolutionary approach, Proceedings of the IEEE Computers in Cardiology, pp.663-666, 1999.

S. Geman and D. Geman, Stochastic relaxation, gibbs distribution, and the bayesian restoration of images, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.6, issue.6, pp.721-741, 1984.

J. Besag, Spatial interaction and the statistical analysis of lattice systems, Journal of the Royal Statistical Society, vol.36, issue.2, pp.192-236, 1974.

J. Marroquin, Optimal bayesian estimators for image segmentation and surface reconstruction Massachusetts Institute of technology, Artificial Intelligence Laboratory, Tech. Rep. Memo, vol.839, 1985.

S. Z. Li, Ch. 13. Modeling image analysis problems using markov random fields, 1993.
DOI : 10.1016/S0169-7161(03)21015-4

URL : https://hal.archives-ouvertes.fr/hal-00374032

H. Derin and H. Elliot, Modeling and Segmentation of Noisy and Textured Images Using Gibbs Random Fields, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.9, issue.1, pp.39-55, 1987.
DOI : 10.1109/TPAMI.1987.4767871

C. Pellot, A. Herment, M. Sigelle, P. Horain, H. Ma??trema??tre et al., A 3D reconstruction of vascular structures from two X-ray angiograms using an adapted simulated annealing algorithm, IEEE Transactions on Medical Imaging, vol.13, issue.1, pp.48-60, 1994.
DOI : 10.1109/42.276144

T. Tian and M. Shah, Motion estimation and segmentation, Machine Vision and Applications, pp.32-42, 1995.
DOI : 10.1007/BF01246637

P. Haigron, Numérisation de surfaces tridimensionnelles applicationàapplication`applicationà la fabrication de prothèses personnalisées, 1993.

M. Levoy, Efficient ray tracing of volume data, ACM Transactions on Graphics, vol.9, issue.3, pp.245-261, 1990.
DOI : 10.1145/78964.78965

R. R. Galigekere, K. Wiesent, and D. W. Holdsworth, Cone-beam reprojection using projection-matrices, IEEE Transactions on Medical Imaging, vol.22, issue.10, pp.1202-1214, 2003.
DOI : 10.1109/TMI.2003.817787

R. Haralick and L. Shapiro, Computer and Robot Vision, 1993.

W. C. Jaggi, A. S. Karl, and . Willsky, Estimation of dynamically evolving ellipsoids with applications to medical imaging, IEEE Transactions on Medical Imaging, vol.14, issue.2, pp.249-258, 1995.
DOI : 10.1109/42.387706

P. Milanfar, W. C. Karl, and A. S. Willsky, Reconstructing Binary Polygonal Objects from Projections: A Statistical View, CVGIP: Graphical Models and Image Processing, pp.371-391, 1994.
DOI : 10.1006/cgip.1994.1034

R. N. Ghanem, C. Ramanathan, P. Jia, and Y. Rudy, Heart-surface reconstruction and ecg electrodes localization using fluoroscopy, epipolar geometry and stereovision: application to noninvasive imaging of cardiac electrical activity, IEEE Transactions on Medical Imaging, vol.22, issue.10, pp.1307-1318, 2003.
DOI : 10.1109/TMI.2003.818263

W. Karl, G. Verghese, and A. Willsky, Reconstructing Ellipsoids from Projections, CVGIP: Graphical Models and Image Processing, vol.56, issue.2, pp.124-139, 1994.
DOI : 10.1006/cgip.1994.1012

T. F. Cootes and C. J. Taylor, Statistical models of appearance for computer vision, 2001.

J. Besag, Nearest-neighbour systems and the auto-logistic model for binary data, Journal of the Royal Statistical Society, vol.34, pp.75-83, 1972.

E. Dougherty, Probability and Statistics for the Engineering, Computing and Physical Sciences, 1990.

Y. Bresler and A. Macovski, Three-dimensional reconstruction from projections with incomplete and noisy data by object estimation, IEEE Transactions on Acoustics, Speech, and Signal Processing, vol.35, issue.8, pp.1139-1152, 1987.
DOI : 10.1109/TASSP.1987.1165270

M. Bertero, T. Poggio, and V. Torre, Ill-posed problems in early vision, Proceedings of the IEEE, vol.76, issue.8, 1987.
DOI : 10.1109/5.5962

S. Kirkpatrick, C. Gelatt, and M. Vecchi, Optimization by simulated annealing, Readings in Computer Vision, pp.606-615, 1982.
DOI : 10.1142/9789812799371_0035

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.123.7607

W. Schroeder, K. Martin, and B. Lorensen, The Visualization Toolkit, 1998.
DOI : 10.1016/B978-012387582-2/50032-0

W. Chang, T. Huang, and M. Arrow, Modeling, analysis, and visualization of left ventricle shape and motion by hierarchical decomposition, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.16, issue.4, pp.342-356, 1994.
DOI : 10.1109/34.277589

X. Riot, Quelques aspects de l'imagerie 3D et de telemedicine The University of Rennes 1, Image and Signal Processing Laboratory, 1997.

C. Slump and J. Gerbrands, A network flow approach to reconstruction of the left ventricle from two projections, Computer Graphics and Image Processing, vol.18, issue.1, pp.18-36, 1982.
DOI : 10.1016/0146-664X(82)90097-1

H. Lehmkuhl, T. Machning, B. Eicker, K. Barth, K. Reynen et al., Digital subtraction angiography: Feasibility of densitometric measurements obtained by monoplane area-length-method, Proceeding of the IEEE Computers in Cardiology, pp.29-32, 1993.

M. Creutz, Microcanonical Monte Carlo Simulation, Physical Review Letters, vol.50, issue.19, pp.1411-1414, 1983.
DOI : 10.1103/PhysRevLett.50.1411

J. Besag, Statistical analysis of dirty pictures*, Journal of Applied Statistics, vol.6, issue.5-6, pp.259-302, 1986.
DOI : 10.1016/0031-3203(83)90012-2