Optimization and evaluation of Luminex performance with supernatants of antigen-stimulated peripheral blood mononuclear cells - Inserm - Institut national de la santé et de la recherche médicale Accéder directement au contenu
Article Dans Une Revue BMC Immunology Année : 2015

Optimization and evaluation of Luminex performance with supernatants of antigen-stimulated peripheral blood mononuclear cells

Résumé

AbstractBackgroundThe Luminex bead-based multiplex assay is useful for quantifying immune mediators such as cytokines and chemokines. Cross-comparisons of reagents for this technique from different suppliers have already been performed using serum or plasma but rarely with supernatants collected from antigen-stimulated peripheral blood mononuclear cells (PBMC). Here, we first describe an optimization protocol for cell culture including quantity of cells and culture duration to obtain reproducible cytokine and chemokine quantifications. Then, we compared three different Luminex kit suppliers.ResultsIntraclass correlation coefficients (ICCs) for a 2-days stimulation protocol were >0.8 for IFNγ and Perforin. The specific concentration was maximal after two or five days of stimulation, depending on the analyte, using 0.5 million PBMC per well, a cell quantity that gave the same level of specific cytokine secretion as 1.0 million. In the second part of the study, Luminex kits from Millipore showed a better working range than Bio-Rad and Ozyme ones. For tuberculin purified protein derivative (PPD)-stimulated samples, the overall mean pooled coefficients of variation (CVs) for all donors and all cytokines was 17.2 % for Bio-Rad, 19.4 % for Millipore and 26.7 % for Ozyme. Although the different kits gave cytokine concentrations that were generally compatible, there were discrepancies for particular cytokines. Finally, evaluation of precision and reproducibility of a 15-plex Millipore kit using a “home-made” internal control showed a mean intra-assay CV <13 % and an inter-assay CV <18 % for each cytokine concentration.ConclusionsA protocol with a single round of stimulation but with two time points gave the best results for assaying different cytokines. Millipore kits appear to be slightly more sensitive than those from Bio-Rad and Ozyme. However, we conclude that the panel of analytes that need to be quantified should be the main determinant of kit selection. Using an internal control we demonstrated that a 15-plex magnetic Milliplex kit displayed good precision and reproducibility. Our findings should help optimize assays for evaluating immune responses during the course of disease or infection, or in response to vaccine or therapy.
Fichier principal
Vignette du fichier
12865_2016_Article_182.pdf (1.16 Mo) Télécharger le fichier
12865_2016_182_MOESM1_ESM.pdf (110.49 Ko) Télécharger le fichier
12865_2016_182_MOESM2_ESM.pdf (110.49 Ko) Télécharger le fichier
12865_2016_182_MOESM3_ESM.pdf (184.4 Ko) Télécharger le fichier
12865_2016_182_MOESM4_ESM.pdf (27 Ko) Télécharger le fichier
12865_2016_182_MOESM5_ESM.pdf (98.14 Ko) Télécharger le fichier
12865_2016_182_MOESM6_ESM.pdf (6.55 Ko) Télécharger le fichier
12865_2016_182_MOESM7_ESM.pdf (252.7 Ko) Télécharger le fichier
12865_2016_182_MOESM8_ESM.pdf (14.97 Ko) Télécharger le fichier
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution
Origine : Publication financée par une institution

Dates et versions

inserm-01395760 , version 1 (11-11-2016)

Identifiants

Citer

Mathieu Surénaud, Céline Manier, Laura Richert, Rodolphe Thiébaut, Yves Levy, et al.. Optimization and evaluation of Luminex performance with supernatants of antigen-stimulated peripheral blood mononuclear cells. BMC Immunology, 2015, 17 (1), pp.44. ⟨10.1186/s12865-016-0182-8⟩. ⟨inserm-01395760⟩
159 Consultations
726 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More