J. Burger, R. Luijendijk, W. Hop, J. Halm, E. Verdaasdonk et al., Long-term Follow-up of a Randomized Controlled Trial of Suture Versus Mesh Repair of Incisional Hernia, Transactions of the ... Meeting of the American Surgical Association, vol.CXXII, issue.&NA;, pp.578-583, 2004.
DOI : 10.1097/01.sla.0000141193.08524.e7

V. Shankaran, D. Weber, R. Reed, and F. Luchette, A Review of Available Prosthetics for Ventral Hernia Repair, Annals of Surgery, vol.253, issue.1, pp.16-26, 2011.
DOI : 10.1097/SLA.0b013e3181f9b6e6

M. Chand, J. On, K. Bevan, H. Mostafid, and A. Venkatsubramaniam, Mesh erosion following laparoscopic incisional hernia repair, Hernia, vol.17, issue.2, pp.223-226, 2012.
DOI : 10.1007/s10029-010-0727-3

S. Blanquer, O. Guillaume, V. Letouzey, L. Lemaire, F. Franconi et al., New magnetic-resonance-imaging-visible poly(??-caprolactone)-based polyester for biomedical applications, Acta Biomaterialia, vol.8, issue.3, pp.1339-1347, 2012.
DOI : 10.1016/j.actbio.2011.11.009

URL : https://hal.archives-ouvertes.fr/hal-00680748

N. Kramer, H. Donker, J. Otto, M. Hodenius, J. Senegas et al., A Concept for Magnetic Resonance Visualization of Surgical Textile Implants, Investigative Radiology, vol.45, issue.8, pp.477-483, 2010.
DOI : 10.1097/RLI.0b013e3181e53e38

J. Zhou, J. Payen, D. Wilson, R. Traystman, and P. Van-zijl, Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI, Nature Medicine, vol.9, issue.8, pp.1085-1090, 2003.
DOI : 10.1038/nm907

J. Zhou, B. Lal, D. Wilson, J. Laterra, P. Van-zijl et al., Amide proton transfer (APT) contrast for imaging of brain tumors NMR imaging of labile proton exchange, Magn Reson Med J Magn Reson, vol.5086, issue.801, pp.1120-1126164, 1990.

K. Ward, A. Aletras, and R. Balaban, A New Class of Contrast Agents for MRI Based on Proton Chemical Exchange Dependent Saturation Transfer (CEST), Journal of Magnetic Resonance, vol.143, issue.1, pp.79-87, 2000.
DOI : 10.1006/jmre.1999.1956

C. Deeken, K. Faucher, and B. Matthews, A review of the composition, characteristics, and effectiveness of barrier mesh prostheses utilized for laparoscopic ventral hernia repair, Surgical Endoscopy, vol.94, issue.2, pp.566-575, 2012.
DOI : 10.1007/s00464-011-1899-3

J. Balique, S. Benchetrit, J. Bouillot, J. Flament, C. Gouillat et al., Intraperitoneal treatment of incisional and umbilical hernias using an innovative composite mesh: four-year results of a prospective multicenter clinical trial, Hernia, vol.17, issue.1, pp.68-74, 2005.
DOI : 10.1007/s10029-004-0300-z

C. Jones, M. Schlosser, P. Van-zijl, M. Pomper, X. Golay et al., Amide proton transfer imaging of human brain tumors at 3T, Magnetic Resonance in Medicine, vol.54, issue.3, pp.585-592, 2006.
DOI : 10.1002/mrm.20989

M. Rosen, M. Van-amerongen, M. Harmsen, A. Petersen, G. Kors et al., Polyester-based mesh for ventral hernia repair: is it safe? The enzymatic degradation of scaffolds and their replacement by vascularized extracellular matrix in the murine myocardium Chemical exchange saturation transfer (CEST): what is in a name and what isn't?, Am J Surg Biomaterials Magn Reson Med Magn Reson Med, vol.197276566, issue.163, pp.353-3592247, 2006.

O. Mougin, R. Coxon, A. Pitiot, and P. Gowland, Magnetization transfer phenomenon in the human brain at 7??T, NeuroImage, vol.49, issue.1, pp.272-281, 2010.
DOI : 10.1016/j.neuroimage.2009.08.022

Z. Wen, S. Hu, F. Huang, X. Wang, L. Guo et al., MR imaging of high-grade brain tumors using endogenous protein and peptide-based contrast, NeuroImage, vol.51, issue.2, pp.616-622, 2010.
DOI : 10.1016/j.neuroimage.2010.02.050

J. Zhou, J. Blakeley, J. Hua, M. Kim, J. Laterra et al., Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging, Magnetic Resonance in Medicine, vol.15, issue.4, pp.842-849, 2008.
DOI : 10.1002/mrm.21712

H. Zhu, C. Jones, P. Van-zijl, P. Barker, J. Zhou et al., Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain Amide proton transfer imaging of the breast at 3 T: Establishing reproducibility and possible feasibility assessing chemotherapy response CEST-FISP: a novel technique for rapid chemical exchange saturation transfer MRI at 7 T, Magn Reson Med Magn Reson Med Magn Reson Med, vol.6465, issue.212, pp.638-644432, 2010.

M. Kim, J. Gillen, B. Landman, J. Zhou, P. Van-zijl et al., Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST), Magn Reson Med Proc Natl Acad Sci U S A, vol.61104, issue.2411, pp.1441-14504359, 2007.