J. Detre, J. Leigh, D. Williams, and A. Koretsky, Perfusion imaging, Magnetic Resonance in Medicine, vol.3, issue.1, pp.37-45, 1992.
DOI : 10.1002/mrm.1910230106

J. Chen, D. Licht, and S. Smith, Arterial spin labeling perfusion MRI in pediatric arterial ischemic stroke: Initial experiences, Journal of Magnetic Resonance Imaging, vol.11, issue.2, pp.282-290, 2009.
DOI : 10.1002/jmri.21641

B. Duhameau, J. Ferre, and P. Jannin, Chronic and treatment-resistant depression: A study using arterial spin labeling perfusion MRI at 3Tesla, Psychiatry Research: Neuroimaging, vol.182, issue.2, pp.111-116, 2010.
DOI : 10.1016/j.pscychresns.2010.01.009

URL : https://hal.archives-ouvertes.fr/inserm-00546501

K. Kamagata, Y. Motoi, and M. Hori, Posterior hypoperfusion in parkinson's disease With and without dementia measured with arterial spin labeling MRI, Journal of Magnetic Resonance Imaging, vol.54, issue.Pt 4, pp.803-807, 2011.
DOI : 10.1002/jmri.22515

J. Perthen, M. Bydder, K. Restom, and T. Liu, SNR and functional sensitivity of BOLD and perfusion-based fMRI using arterial spin labeling with spiral SENSE at 3 T, Magnetic Resonance Imaging, vol.26, issue.4, pp.513-522, 2008.
DOI : 10.1016/j.mri.2007.10.008

H. Raoult, J. Petr, and E. Bannier, Arterial spin labeling for motor activation mapping at 3T with a 32-channel coil: Reproducibility and spatial accuracy in comparison with BOLD fMRI, NeuroImage, vol.58, issue.1, pp.157-167, 2011.
DOI : 10.1016/j.neuroimage.2011.06.011

URL : https://hal.archives-ouvertes.fr/inserm-00604941

C. Warmuth, M. Gunther, and C. Zimmer, Quantification of Blood Flow in Brain Tumors: Comparison of Arterial Spin Labeling and Dynamic Susceptibility-weighted Contrast-enhanced MR Imaging, Radiology, vol.228, issue.2, pp.523-532, 2003.
DOI : 10.1148/radiol.2282020409

J. Wang, D. Alsop, and L. Li, Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla, Magnetic Resonance in Medicine, vol.44, issue.2, pp.242-254, 2002.
DOI : 10.1002/mrm.10211

Z. Wang, J. Wang, T. Connick, G. Wetmore, and J. Detre, Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T, Magnetic Resonance in Medicine, vol.42, issue.3, pp.732-737, 2005.
DOI : 10.1002/mrm.20574

J. Lupo, M. Lee, and E. Han, Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction, Journal of Magnetic Resonance Imaging, vol.43, issue.3, pp.520-529, 2006.
DOI : 10.1002/jmri.20673

J. De-zwart, P. Ledden, P. Van-gelderen, J. Bodurka, R. Chu et al., Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla, Magnetic Resonance in Medicine, vol.13, issue.1, pp.22-26, 2004.
DOI : 10.1002/mrm.10678

W. Luh, E. Wong, P. Bandettini, and J. Hyde, QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling, Magnetic Resonance in Medicine, vol.29, issue.6, pp.1246-1254, 1999.
DOI : 10.1002/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO;2-N

E. Wong, R. Buxton, and L. Frank, Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling, NMR in Biomedicine, vol.31, issue.4-5, pp.237-249, 1997.
DOI : 10.1002/(SICI)1099-1492(199706/08)10:4/5<237::AID-NBM475>3.0.CO;2-X

C. Preibisch, T. Wallenhorst, R. Heidemann, F. Zanella, and H. Lanfermann, Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T, Journal of Magnetic Resonance Imaging, vol.45, issue.3, pp.590-598, 2008.
DOI : 10.1002/jmri.21191

J. Petr, J. Ferr-e, J. Gauvrit, and C. Barillot, Denoising arterial spin labeling MRI using tissue partial volume, Medical Imaging 2010: Image Processing, pp.76230-76239, 2010.
DOI : 10.1117/12.844443

URL : https://hal.archives-ouvertes.fr/inserm-00601147

O. Dietrich, J. Raya, S. Reeder, M. Reiser, and S. Schoenberg, Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters, Journal of Magnetic Resonance Imaging, vol.34, issue.2, pp.375-385, 2007.
DOI : 10.1002/jmri.20969

R. Bammer and S. Schoenberg, Current Concepts and Advances in Clinical Parallel Magnetic Resonance Imaging, Topics in Magnetic Resonance Imaging, vol.15, issue.3, pp.129-158, 2004.
DOI : 10.1097/01.rmr.0000139666.23921.27

G. Kruger and G. Glover, Physiological noise in oxygenation-sensitive magnetic resonance imaging, Magnetic Resonance in Medicine, vol.11, issue.5, pp.631-637, 2001.
DOI : 10.1002/mrm.1240

F. Vogt, G. Antoch, and P. Hunold, Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity, Journal of Magnetic Resonance Imaging, vol.45, issue.4, pp.376-382, 2005.
DOI : 10.1002/jmri.20288

Y. Bhagat, D. Emery, S. Naik, T. Yeo, and C. Beaulieu, Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging, AJNR Am J Neuroradiol, vol.28, pp.293-298, 2007.