Accuracy of perfusion MRI with high spatial but low temporal resolution to assess invasive breast cancer response to neoadjuvant chemotherapy: a retrospective study. - Inserm - Institut national de la santé et de la recherche médicale Accéder directement au contenu
Article Dans Une Revue BMC Cancer Année : 2011

Accuracy of perfusion MRI with high spatial but low temporal resolution to assess invasive breast cancer response to neoadjuvant chemotherapy: a retrospective study.

Anne-Sophie Hamy
  • Fonction : Auteur
  • PersonId : 910126
Marc Espié
  • Fonction : Auteur
  • PersonId : 910128

Résumé

UNLABELLED: ABSTRACT: BACKGROUND: To illustrate that Breast-MRI performed in high spatial resolution and low temporal resolution (1 minute) allows the measurement of kinetic parameters that can assess the final pathologic response to neoadjuvant chemotherapy in breast cancer. METHODS: Breast-MRI was performed in 24 women before and after treatment. Eight series of 1.11 minute-duration were acquired with a sub-millimeter spatial resolution. Transfer constant (Ktrans) and leakage space (Ve) were calculated using measured and theoretical Arterial Input Function (AIF). Changes in kinetic parameters after treatment obtained with both AIFs were compared with final pathologic response graded in non-responder (< 50% therapeutic effect), partial-responder (> 50% therapeutic effect) and complete responder. Accuracies to identify non-responders were compared with receiver operating characteristic curves. RESULTS: With measured-AIF, changes in kinetic parameters measured after treatment were in agreement with the final pathological response. Changes in Ve and Ktrans were significantly different between non-(N = 11), partial-(N = 7), and complete (N = 6) responders, (P = 0.0092 and P = 0.0398 respectively). A decrease in Ve of more than -72% and more than -84% for Ktrans resulted in 73% sensitivity for identifying non-responders (specificity 92% and 77% respectively). A decrease in Ve of more than -87% helped to identify complete responders (Sensitivity 89%, Specificity 83%). With theoretical-AIF, changes in kinetic parameters had lower accuracy. CONCLUSION: There is a good agreement between pathological findings and changes in kinetic parameters obtained with breast-MRI in high spatial and low temporal resolution when measured-AIF is used. Further studies are necessary to confirm whether MRI contrast kinetic parameters can be used earlier as a response predictor to neoadjuvant chemotherapy.

Domaines

Cancer
Fichier principal
Vignette du fichier
1471-2407-11-361.pdf (297.72 Ko) Télécharger le fichier
1471-2407-11-361.xml (110.72 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Format : Autre
Loading...

Dates et versions

inserm-00623267 , version 1 (13-09-2011)

Identifiants

Citer

Cédric de Bazelaire, Raphael Calmon, Isabelle Thomassin, Clément Brunon, Anne-Sophie Hamy, et al.. Accuracy of perfusion MRI with high spatial but low temporal resolution to assess invasive breast cancer response to neoadjuvant chemotherapy: a retrospective study.. BMC Cancer, 2011, 11 (1), pp.361. ⟨10.1186/1471-2407-11-361⟩. ⟨inserm-00623267⟩
250 Consultations
307 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More