C. Bjarkam, M. Pedersen, and J. Sorensen, New strategies for embedding, orientation and sectioning of small brain specimens enable direct correlation to MR-images, brain atlases, or use of unbiased stereology, Journal of Neuroscience Methods, vol.108, issue.2, pp.153-162, 2001.
DOI : 10.1016/S0165-0270(01)00383-1

D. Bronson, H. Bidmon, K. Tomaschko, and W. Stumpf, Novel applications of acrylamide for cryosectioning of isolated cells, tissues, and arthropods., Journal of Histochemistry & Cytochemistry, vol.39, issue.9, pp.1289-93, 1991.
DOI : 10.1177/39.9.1918945

D. Gardella, W. Hatton, H. Rind, G. Rosen, V. Bartheld et al., Differential tissue shrinkage and compression in the z-axis: implications for optical disector counting in vibratome-, plastic- and cryosections, Journal of Neuroscience Methods, vol.124, issue.1, pp.45-59, 2003.
DOI : 10.1016/S0165-0270(02)00363-1

A. Goldszal, O. Tretiak, P. Hand, S. Bhasin, and D. Mceachron, Three-Dimensional Reconstruction of Activated Columns from 2-[14C]Deoxy-?-glucose Data, NeuroImage, vol.2, issue.1, pp.9-20, 1995.
DOI : 10.1006/nimg.1995.1004

A. Goshtasby, Piecewise linear mapping functions for image registration, Pattern Recognition, vol.19, issue.6, pp.459-66, 1986.
DOI : 10.1016/0031-3203(86)90044-0

A. Hess, K. Lohmann, E. Gundelfinger, and H. Scheich, A new method for reliable and efficient reconstruction of 3-dimensional images from autoradiographs of brain sections, Journal of Neuroscience Methods, vol.84, issue.1-2, pp.77-86, 1998.
DOI : 10.1016/S0165-0270(98)00102-2

L. Hibbard and R. Hawkins, Objective image alignment for three-dimensional reconstruction of digital autoradiograms, Journal of Neuroscience Methods, vol.26, issue.1, pp.55-74, 1988.
DOI : 10.1016/0165-0270(88)90129-X

D. Hill, P. Batchelor, M. Holden, and D. Hawkes, Medical image registration, Physics in Medicine and Biology, vol.46, issue.3, pp.1-45, 2001.
DOI : 10.1088/0031-9155/46/3/201

URL : https://hal.archives-ouvertes.fr/inria-00615977

J. Humm, D. Ballon, Y. Hu, S. Ruan, C. Chui et al., A stereotactic method for the three-dimensional registration of multi-modality biologic images in animals: NMR, PET, histology, and autoradiography, Medical Physics, vol.21, issue.9, pp.2303-2317, 2003.
DOI : 10.1118/1.1600738

J. Maintz and M. Viergever, A survey of medical image registration, Medical Image Analysis, vol.2, issue.1, pp.1-36, 1998.
DOI : 10.1016/S1361-8415(01)80026-8

G. Malandain, E. Bardinet, K. Nelissen, and W. Vanduffel, Fusion of autoradiographs with an MR volume using 2-D and 3-D linear transformations, NeuroImage, vol.23, issue.1, pp.111-138, 2004.
DOI : 10.1016/j.neuroimage.2004.04.038

URL : https://hal.archives-ouvertes.fr/inria-00615651

M. Mega, S. Chen, P. Thompson, R. Woods, T. Karaca et al., Mapping Histology to Metabolism: Coregistration of Stained Whole-Brain Sections to Premortem PET in Alzheimer's Disease, NeuroImage, vol.5, issue.2, pp.147-53, 1997.
DOI : 10.1006/nimg.1996.0255

C. Nikou, F. Heitz, A. Nehlig, I. Namer, and J. Armspach, A robust statistics-based global energy function for the alignment of serially acquired autoradiographic sections, Journal of Neuroscience Methods, vol.124, issue.1, pp.93-102, 2003.
DOI : 10.1016/S0165-0270(02)00369-2

S. Ourselin, A. Roche, G. Subsol, X. Pennec, and N. Ayache, Reconstructing a 3D structure from serial histological sections, Image and Vision Computing, vol.19, issue.1-2, pp.25-31, 2001.
DOI : 10.1016/S0262-8856(00)00052-4

URL : https://hal.archives-ouvertes.fr/cea-00333669

A. Rangarajan, H. Chui, E. Mjolsness, S. Pappu, L. Davachi et al., A robust point-matching algorithm for autoradiograph alignment, Medical Image Analysis, vol.1, issue.4, pp.379-98, 1997.
DOI : 10.1016/S1361-8415(97)85008-6

O. Sakurada, C. Kennedy, J. Jehle, J. Brown, G. Carbin et al., Measurement of local cerebral blood flow with iodo [14C] antipyrine, Am J Physiol, vol.234, pp.59-66, 1978.

T. Schormann and K. Zilles, Three-Dimensional linear and nonlinear transformations: An integration of light microscopical and MRI data, Human Brain Mapping, vol.960, issue.5-6, pp.339-386, 1998.
DOI : 10.1002/(SICI)1097-0193(1998)6:5/6<339::AID-HBM3>3.0.CO;2-Q

J. Sorensen, C. Bjarkam, E. Danielsen, C. Simonsen, and F. Geneser, Oriented sectioning of irregular tissue blocks in relation to computerized scanning modalities:, Journal of Neuroscience Methods, vol.104, issue.1, pp.93-101, 2000.
DOI : 10.1016/S0165-0270(00)00330-7

J. Streicher, W. Weninger, and G. Muller, External marker-based automatic congruencing: A new method of 3D reconstruction from serial sections, The Anatomical Record, vol.13, issue.4, pp.583-602, 1997.
DOI : 10.1002/(SICI)1097-0185(199708)248:4<583::AID-AR10>3.0.CO;2-L

A. Toga and P. Thompson, The role of image registration in brain mapping, Image and Vision Computing, vol.19, issue.1-2, pp.3-24, 2001.
DOI : 10.1016/S0262-8856(00)00055-X

B. Williams and M. Doyle, An internet atlas of mouse development, Computerized Medical Imaging and Graphics, vol.20, issue.6, pp.433-480, 1996.
DOI : 10.1016/S0895-6111(96)00041-9

C. Zarow, T. Kim, M. Singh, and H. Chui, A standardized method for brain-cutting suitable for both stereology and MRI-brain co-registration, Journal of Neuroscience Methods, vol.139, issue.2, pp.209-224, 2004.
DOI : 10.1016/j.jneumeth.2004.04.034