Abstract : An experimental binary radiotherapy proposes the concomitant use of a high-Z compound and synchrotron X rays for enhancing radiation dose selectively in tumours by a photoelectric effect. This study aimed at measuring the resulting dose enhancement in irradiated material. A doped Fricke gel dosemeter model was manufactured with 10 mg ml(-1) of iodine (Telebrix) or barium (Micropaque). Samples were irradiated with a monochromatic synchrotron beam at 33.5, 50, 65 and 80 keV. The ensuing enhancement of the sensitivity of the dosemeter was derived from the nuclear magnetic resonance relaxation rates measured at different X-ray doses. Our results demonstrate (1) the preservation of a linear relationship between relaxation rates and X-ray doses for dosemeters doped with high-Z atoms and (2) a clear energy-dependent sensitivity enhancement for barium-doped Fricke gels. This enhancement was neither reproducible with iodinated compounds nor clearly related to the expected dose enhancement factor. However 1% barium sulphate in the gel could significantly improve the gel's response when it was irradiated by low-energy X rays.
Type de document :
Article dans une revue
Radiation Protection Dosimetry, Oxford University Press (OUP), 2005, 117 (4), pp.425-31. 〈10.1093/rpd/nci313〉
Liste complète des métadonnées

http://www.hal.inserm.fr/inserm-00388937
Contributeur : Raphael Serduc <>
Soumis le : mercredi 27 mai 2009 - 17:16:45
Dernière modification le : vendredi 29 mai 2009 - 15:31:55

Lien texte intégral

Identifiants

Collections

UGA

Citation

Stéphanie Corde, Jean-François Adam, Marie-Claude Biston, Aurélie Joubert, Anne-Marie Charvet, et al.. Sensitivity variation of doped Fricke gel irradiated with monochromatic synchrotron X rays between 33.5 and 80 keV.. Radiation Protection Dosimetry, Oxford University Press (OUP), 2005, 117 (4), pp.425-31. 〈10.1093/rpd/nci313〉. 〈inserm-00388937〉

Partager

Métriques

Consultations de la notice

60